3Z4L Laser Micrometer Protocol
Memory Switch Set 2 (3000-series, High-speed Type)
(Sequence No. 422 (Hex 01A6))
This sequence sets memory switches.
Send Data Word Allocation (3rd Operand of PMCR(260))
First word of send
data
Receive Data Word Allocation (4th Operand of PMCR(260))
None.
Note Memory switches cannot be set when DIP switch SW3, pin 5 of the Laser Micrometer is not turned ON.
Simple AVG Times Set (3000-series, High-speed Type)
(Sequence No. 423 (Hex 01A7))
This sequence uses the simple average as the averaging method and sets the averaging times per measure-
ment interval 4.
Send Data Word Allocation (3rd Operand of PMCR(260))
First word of send
data
Receive Data Word Allocation (4th Operand of PMCR(260))
None.
Note This sequence cannot be used when DIP switch SW3, pin 5 of the Laser Micrometer is not turned ON.
+0
Number of send data words
+1
W
X
Y
+2
(Undefined)
Offset
Contents (data format)
+0
Number of send data words
(4 digits Hex)
+1
w (1 digit BCD)
x (1 digit BCD)
y (1 digit BCD)
z (1 digit BCD)
+2
v (1 digit BCD)
Note Settings marked with asterisks are required for this protocol.
+0
Number of send data words
+1
Number of averaging times
Offset
Contents (data format)
+0
Number of send data words
(4 digits Hex)
+1
Number of averaging times
(4 digits BCD)
Z
V
0003 (fixed)
0:
Work automatic detection is not performed
1:
Work automatic detection is performed
Diameter detection method (1 scan)
2:
Work automatic detection is performed
Diameter detection method (8 scan)
3:
Work automatic detection is performed
Position detection method (1 scan)
For expansion
0 (fixed)
For expansion
0 (fixed)
For expansion
0 (fixed)
*0: Error data exclusion function is not used
1: Error data exclusion function is used
0002 (fixed)
1 to 2048
Appendix K
Data
Data