Visual Inspection System Protocol
Receive Data Word Allocation (4th Operand of PMCR(260))
None.
Scene Switching (Arbitrary) (Sequence No. 492 (Hex 01EC))
This sequence switches to a designated scene No.
Send Data Word Allocation (3rd Operand of PMCR(260))
First word of
send data
Receive Data Word Allocation (4th Operand of PMCR(260))
None.
Measurement, Inspection Termination (Sequence No. 493 (Hex
01ED))
This sequence terminates the measurement and returns to the home menu.
Send Data Word Allocation (3rd Operand of PMCR(260))
None.
Receive Data Word Allocation (4th Operand of PMCR(260))
None.
General-purpose Command (Send) (Sequence No. 494 (Hex
01EE))
This sequence can set and execute commands that are not otherwise supported. The delimiter (CR+LF) is
automatically attached to the send data.
Send Data Word Allocation (3rd Operand of PMCR(260))
First word of
send data
Receive Data Word Allocation (4th Operand of PMCR(260))
None.
Note 1. The processing depends on the command.
2. For a command with a response, use sequence #495.
442
+0
Number of send data words
+1
(Undefined)
Scene No.
Offset
Contents (data format)
+0
Number of send data words
(4 digits BCD)
+1
Scene No. (2 digits BCD)
+0
Number of send data words
+1
Command length
+2
Command
(Undefined)
~
Offset
Contents (data format)
+0
Number of send data words
(4 digits Hex)
+1
Command length (4 digits Hex)
+2 to
Command (ASCII)
0002
00 to 15
~
0003 to 00FA (3 to 250 decimal)
0001 to 01F0 (1 to 496 decimal)
Specify ASCII data.