Omron CS1W-SCU21 Operation Manual page 374

Hide thumbs Also See for CS1W-SCU21:
Table of Contents

Advertisement

K3T# Intelligent Signal Processor Protocol
The K3T# Intelligent Signal Processor Protocol is used to make various settings or control remotely the Intelli-
gent Signal Processor connected to the Serial Communications Unit/Board via RS-232C or RS-422/485 cable.
Protocol Configuration
The configuration of the K3T# Intelligent Signal Processor Protocol is shown as follows:
Sequence
Communications
No.
sequence name
300 (012C) Reset (by unit number)
301 (012D) Reset (continuous units)
302 (012E)
Write set value (by unit
number)
303 (012F)
Write set value HH (con-
tinuous units)
304 (0130)
Write set value H (contin-
uous units)
305 (0131)
Write set value L (contin-
uous units)
306 (0132)
Write set value LL (con-
tinuous units)
307 (0133)
Write set value with bank
(by unit number)
308 (0134)
Write set value HH with
bank (continuous units)
309 (0135)
Write set value H with
bank (continuous units)
310 (0136)
Write set value L with
bank (continuous units)
311 (0137)
Write set value LL with
bank (continuous units)
312 (0138)
Write set value O5 with
bank (continuous units)
313 (0139)
Write set value O4 with
bank (continuous units)
314 (013A)
Write set value O3 with
bank (continuous units)
315 (013B)
Write set value O2 with
bank (continuous units)
316 (013C) Write set value O1 with
bank (continuous units)
317 (013D) Read set value (by unit
number)
318 (013E)
Read set value HH (con-
tinuous units)
Appendix I
Function
Performs the same processing as
when an input is received on the
reset terminal.
Performs the same processing as
when an input is received on the
reset terminal.
Writes the set value HH, H, L, or
LL.
Writes the set value HH.
Writes the set value H.
Writes the set value L.
Writes the set value LL.
Writes the set value to a bank
which is not in use (K3TR: HH to
LL, K3TC: O1 to O5).
Writes the set value HH to a bank
which is not in use.
Writes the set value H to a bank
which is not in use.
Writes the set value L to a bank
which is not in use.
Writes the set value LL to a bank
which is not in use.
Writes the set value O5 to a bank
which is not in use.
Writes the set value O4 to a bank
which is not in use.
Writes the set value O3 to a bank
which is not in use.
Writes the set value O2 to a bank
which is not in use.
Writes the set value O1 to a bank
which is not in use.
Reads the set value HH, H, L, or
LL.
Reads the set value HH.
Ladder interface
Send word
Receive word
allocation
allocation
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
Yes
Yes
Yes
Notes
See
Note1
See
Note1
See
Note1
See
Note1
See
Note1
See
Note2
See
Note1
See
Note1
See
Note1
See
Note1
See
Note1
See
Note1
See
Note1
See
Note1
See
Note1
See
Note1
See
Note1
355