Visual Inspection System Protocol
Continuous Measurement Execution (Interrupt) (F300)
(Sequence No. 462 (Hex 01CE))
This sequence carries out continuously setting the F300 and stores measurement results in the specified
words. The interrupt notification method is used for the receive data. The interrupt No. is 102.
Send Data Word Allocation (3rd Operand of PMCR(260))
None.
Receive Data Word Allocation (4th Operand of PMCR(260))
Receive data
storage words
Note 1. Exponential expressions are used for numbers larger than 9999999.999 and smaller than –999999.9.
2. The number of measurement items is up to 5, but only one window number can be read.
436
Number of receive data words
+0
+1
(Undefined)
+2
(Undefined)
Decimal portion
+3
Integer portion
+4
+5
Sign
0
+6
Decimal portion
Integer portion
+7
+8
Sign
0
+9
Decimal portion
Integer portion
+10
+11
Sign
0
+12
Decimal portion
Integer portion
+13
+14
Sign
0
+15
Decimal portion
Integer portion
+16
+17
Sign
0
Offset
Content (data format)
+0
Number of receive data words
(4 digits Hex)
+1
Window No. (2 digits BCD)
+2
Evaluation result (1 digit BCD)
+3 to +5 Measurement value (decimal portion)
(3 digits BCD)
Measurement value (integer portion)
(7 digits BCD)
Measurement value (sign)
(1 digit)
+6 to +8 Same as +3 to +5.
+9 to
Same as +3 to +5.
+11
+12 to
Same as +3 to +5.
+14
+15 to
Same as +3 to +5.
+17
Window No.
Evaluation
result
Data 1
Data 2
Data 3
Data 4
Data 5
0006:
0009:
000C:
000F:
0012:
00 to 07
0: OK
1: NG
Example
–123.456
+3
+4
+5
F is stored for negative values.
Same as +3 to +5.
Same as +3 to +5.
Same as +3 to +5.
Same as +3 to +5.
Appendix L
Data
1 measurement item
2 measurement items
3 measurement items
4 measurement items
5 measurement items
Example
+123.456
3456
+3
3456
0012
+4
0012
F000
0000