Visual Inspection System Protocol
3. Turn ON the Abort Switch to end this sequence.
Inspection Execution and Character Inspection (F350)
(Sequence No. 473 (Hex 01D9))
This sequence carries out one inspection and outputs the inspection results to a video monitor.
Send Data Word Allocation (3rd Operand of PMCR(260))
None.
Receive Data Word Allocation (4th Operand of PMCR(260))
None.
Character String Inspection and Character Inspection (F350)
(Sequence No. 474 (Hex 01DA))
This sequence changes the inspection character string of a designated inspection area No. to a designated
character string.
Send Data Word Allocation (3rd Operand of PMCR(260))
First word of send
data
Receive Data Word Allocation (4th Operand of PMCR(260))
None.
Camera Change (Decrease by 1) (F200/300) (Sequence No. 480
(Hex 01E0))
This sequence decreases the display camera No. by 1.
Send Data Word Allocation (3rd Operand of PMCR(260))
None.
Receive Data Word Allocation (4th Operand of PMCR(260))
None.
Camera Change (Increase by 1) (F200/300) (Sequence No. 481
(Hex 01E1))
This sequence increases the display camera No. by 1.
440
Number of send data words
+0
+1
+2
(Undefined)
Designated character string
+3
~
Designated character string
Offset
Contents (data format)
+0
Number of send data words
(4 digits Hex)
+1
Number of designated character
strings (4 digits Hex)
+2
Inspection area No.
(1 digit BCD)
+3 to
Number of designated character
strings (ASCII)
Inspection area No.
Number of designated character strings
0004 to 000F (0004 to 0015 decimal)
0000 to 0018 (0000 to 0024 decimal)
0 to 7