Omron CS1W-SCU21 Operation Manual page 453

Hide thumbs Also See for CS1W-SCU21:
Table of Contents

Advertisement

Visual Inspection System Protocol
4. The priority of measurement items being output are as follows:
Area
Center of gravity X, Center of gravity Y
Displacement in center of gravity X (reserved), displacement in center of gravity Y (reserved)
Main axis angle
Main axis angle aberration (reserved)
Edge angle
Edge angle (reserved)
Center X, center Y
Center X aberration (reserved), center Y aberration (reserved)
Inclination
Inclination aberration (reserved)
Intersecting point X, intersecting point Y
Intersecting point X aberration (reserved), intersecting point Y aberration (reserved)
Continuous Measurement Execution (Scan) (F300)
(Sequence No. 461 (Hex 01CD))
This sequence carries out continuously the settings of F300 and stores measurement results in the specified
words.
Send Data Word Allocation (3rd Operand of PMCR(260))
None.
Receive Data Word Allocation (4th Operand of PMCR(260))
Receive data
storage words
434
Number of receive data words
+0
+1
(Undefined)
+2
(Undefined)
+3
Decimal portion
Integer portion
+4
+5
Sign
0
Decimal portion
+6
Integer portion
+7
+8
Sign
0
+9
Decimal portion
Integer portion
+10
+11
Sign
0
Decimal portion
+12
Integer portion
+13
+14
Sign
0
Decimal portion
+15
Integer portion
+16
+17
Sign
0
Window No.
Evaluation
result
Data 1
Data 2
Data 3
Data 4
Data 5
Appendix L

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cj1w-scu41

Table of Contents