3Z4L Laser Micrometer Protocol
Measurement Condition Release (3000-series)
(Sequence No. 408 (Hex 0198))
This sequence releases the measurement conditions that have been set.
Send Data Word Allocation (3rd Operand of PMCR(260))
Send data word allocation is similar to that of sequence No. 407 (Measurement Condition Set). However, only
the setting Yes/No flags at +46 to +53 from the send data leading word can be used.
Receive Data Word Allocation (4th Operand of PMCR(260))
None.
Note 1. The following conditions are used when the measurement conditions are released: Segment be-
comes 1, measurement interval becomes 1, the number of sample measurement pulses becomes 1.
2. The following conditions cannot be released with this sequence: error lower limit (EL), error upper lim-
it (EH), error exclusion counter (CNT) of the error data exclusion function (centerless grinder func-
tion).
3. The following settings cannot be released separately using this sequence.
Lower limit, Upper limit
Multistep selection limit
Reference value, analog output scale number
Data output conditions, scheduled print timer
Measurement Condition List Request (3000-series)
(Sequence No. 409 (Hex 0199))
This sequence requests the measurement condition settings that have been set and other settings.
Send Data Word Allocation (3rd Operand of PMCR(260))
None.