Omron CS1W-SCU21 Operation Manual page 413

Hide thumbs Also See for CS1W-SCU21:
Table of Contents

Advertisement

3Z4L Laser Micrometer Protocol
Delimiter Control Code Setting
3Z4L-4000 Series
The delimiter control codes must be set on DIP switch SW1 for the 3Z4L-4000 Series. Turn off pins 4 and 5, set
the delimiter codes to CR+LF, and set the delimiter code control setting in the sequence to CR+LF. See the set-
ting for CR+LF in the following diagram.
394
1
2 3 4 5
6 7 8
Turn OFF.
Turn OFF (to use a general-purpose interface)
Turn ON (to use a general-purpose interface)
Delimiter Setting
Delimiter
CR+LF
Pin
Pin 4
OFF
ON
Pin 5
OFF
OFF
Handshaking
ON:
Control (recognize DRT input)
OFF: 3-wire method (non-protocol)
Baud Rate
Baud rate
1200 2400
Pin
OFF
Pin 1
ON
Pin 2
OFF
OFF
Appendix K
CR
LF
OFF
ON
4800
9600
OFF
ON
ON
ON