Figure 111. USB embedded hypervisor flash device removal
8. If you are instructed to return the hypervisor memory key, follow all packaging
instructions, and use any packaging materials for shipping that are supplied to
you.
Note: You must configure the server not to look for the hypervisor USB drive.
See "Configuring the server" on page 88 for information about disabling
hypervisor support.

Replacing a USB embedded hypervisor flash device

Use this information to replace a USB embedded hypervisor flash device.
About this task
To install a USB hypervisor memory key in the server, complete the following
steps:
Procedure
1. Read the safety information that begins on page "Safety" on page vii and
"Installation guidelines" on page 32.
2. Turn off the server (see "Turning off the server" on page 22) and all attached
peripheral devices. Disconnect all power cords; then, disconnect all external
cables as necessary to replace the device.
3. Remove the server top cover (see "Removing the server top cover" on page
258).
4. Rotate the hot-swap rear hard disk drive cage up (see "Rotating the hot-swap
rear hard disk drive cage up" on page 168.
5. Remove PCI riser-card assembly 1 (see"Removing a PCI riser-card assembly"
on page 206).
Chapter 6. Removing and replacing components