IBM System x3650 M4 BD Type 5466 Installation And Service Manual page 208

Table of Contents

Advertisement

Figure 103. Slot 3
Figure 104. Slot 2 and Slot 1
To install a ServeRAID adapter on the PCI riser-card assembly, complete the
following steps:
Procedure
1. Read the safety information that begins on page "Safety" on page vii and
2. Turn off the server (see "Turning off the server" on page 22) and all attached
3. Remove the server top cover (see "Removing the server top cover" on page
4. If you are installing a new or replacement ServeRAID adapter, touch the
5. If you are installing a new or replacement ServeRAID adapter that uses a
192
System x3650 M4 BD Type 5466: Installation and Service Guide
"Installation guidelines" on page 32.
peripheral devices. Disconnect all power cords; then, disconnect all external
cables from the server.
258).
static-protective package that contains the new ServeRAID adapter to any
unpainted metal surface on the server. Then, remove the ServeRAID adapter
from the package.
battery, complete the following steps:
a. Remove the battery from the ServeRAID adapter package or the battery
package.
b. Install the battery and connect the battery to the ServeRAID controller as
instructed in the documentation that comes with the ServeRAID controller
or the battery, or see "Installing a ServeRAID adapter battery or flash power
module in the remote battery tray" on page 53.