80070608-0a01ffff
Sensor [SensorElementName] has transitioned to non-recoverable.
Explanation: This message is for the use case when an implementation has detected a Sensor transitioned to
non-recoverable.
May also be shown as 800706080a01ffff or 0x800706080a01ffff
Severity: Error
Alert Category: Critical - Power
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0530
SNMP Trap ID: 4
Automatically notify Support: No
User response: If the specified sensor is PS n 12V OC Fault, complete the following steps until the problem is
solved:
1.
Use the IBM Power Configurator utility to determine current system power consumption. For more information
and to download the utility, go to http://www-03.ibm.com/systems/bladecenter/resources/powerconfig.html.
2.
Follow actions in "Power Problems and Solving Power Problems".
If the specified sensor is PS n 12V OV Fault, complete the following steps until the problem is solved:
1.
Check power supply n LED.
2.
Remove the failing power supply.
3.
(Trained technician only) Replace the system board. (n = power supply number)
If the specified sensor is PS n 12V UV Fault, complete the following steps until the problem is solved:
1.
Check power supply n LED.
2.
Remove the failing power supply.
3.
Follow actions in "Power Problems and Solving Power Problems".
4.
(Trained technician only) Replace the system board. (n = power supply number)
If the specified sensor is PS n 12Vaux Fault, complete the following steps until the problem is solved:
1.
Check power supply n LED.
2.
Replace power supply n. (n = power supply number)
80070608-0a02ffff
Sensor [SensorElementName] has transitioned to non-recoverable.
Explanation: This message is for the use case when an implementation has detected a Sensor transitioned to
non-recoverable.
May also be shown as 800706080a02ffff or 0x800706080a02ffff
Severity: Error
Alert Category: Critical - Power
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0530
SNMP Trap ID: 4
Automatically notify Support: No
User response: If the specified sensor is PS n 12V OC Fault, complete the following steps until the problem is
solved:
1.
Use the IBM Power Configurator utility to determine current system power consumption. For more information
and to download the utility, go to http://www-03.ibm.com/systems/bladecenter/resources/powerconfig.html.
2.
Follow actions in "Power Problems and Solving Power Problems".