IBM System x3650 M4 BD Type 5466 Installation And Service Manual page 365

Table of Contents

Advertisement

8007021b-0301ffff
Sensor [SensorElementName] has transitioned to critical from a less severe state. (CPU 1
QPILinkErr)
Explanation: This message is for the use case when an implementation has detected a Sensor transitioned to critical
from less severe.
May also be shown as 8007021b0301ffff or 0x8007021b0301ffff
Severity: Error
Alert Category: Critical - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0522
SNMP Trap ID: 50
Automatically notify Support: No
User response:
1.
Check for a server firmware update.
2.
Make sure that the installed microprocessors are compatible.
3.
(Trained technician only) Replace the microprocessor if the problems still exist
4.
(Trained technician only) Replace the system board if the problems still exist.
8007021b-0302ffff
Sensor [SensorElementName] has transitioned to critical from a less severe state. (CPU 2
QPILinkErr)
Explanation: This message is for the use case when an implementation has detected a Sensor transitioned to critical
from less severe.
May also be shown as 8007021b0302ffff or 0x8007021b0302ffff
Severity: Error
Alert Category: Critical - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0522
SNMP Trap ID: 50
Automatically notify Support: No
User response:
1.
Check for a server firmware update.
2.
Make sure that the installed microprocessors are compatible.
3.
(Trained technician only) Replace the microprocessor if the problems still exist
4.
(Trained technician only) Replace the system board if the problems still exist.
8007021b-0301ffff • 8007021b-0302ffff
Appendix A. Integrated management module II (IMM2) error messages
349

Advertisement

Table of Contents
loading