IBM System x3650 M4 BD Type 5466 Installation And Service Manual page 622

Table of Contents

Advertisement

W.305800B • W.305800E
W.305800B
[W.305800B] DRIVER HEALTH PROTOCOL: Reports 'Reboot' Required Controller.
Explanation: DRIVER HEALTH PROTOCOL: Reports 'Reboot' Required Controller
Severity: Warning
User response: Complete the following steps:
1.
No action required – system will reboot at the end of POST.
2.
If problem persists, switch to backup UEFI or reflash current UEFI image.
3.
(Trained Service Technician Only) Replace system board.
W.305800C
[W.305800C] DRIVER HEALTH PROTOCOL: Reports 'System Shutdown' Required Controller.
Explanation: DRIVER HEALTH PROTOCOL: Reports 'System Shutdown' Required Controller
Severity: Warning
User response: Complete the following steps:
1.
Reboot the system.
2.
If problem persists, switch to backup UEFI or reflash current UEFI image.
3.
(Trained Service Technician Only) Replace system board.
W.305800D
[W.305800D] DRIVER HEALTH PROTOCOL: Disconnect Controller Failed. Requires 'Reboot'.
Explanation: DRIVER HEALTH PROTOCOL: Disconnect Controller Failed. Requires 'Reboot'
Severity: Warning
User response: Complete the following steps:
1.
Reboot the system to reconnect the controller.
2.
If problem persists, switch to backup UEFI or reflash current UEFI image.
3.
(Trained Service Technician Only) Replace system board.
W.305800E
[W.305800E] DRIVER HEALTH PROTOCOL: Reports Invalid Health Status Driver.
Explanation: DRIVER HEALTH PROTOCOL: Reports Invalid Health Status Driver
Severity: Warning
User response: Complete the following steps:
1.
Reboot the system.
2.
If problem persists, switch to backup UEFI or reflash current UEFI image.
3.
(Trained Service Technician Only) Replace system board.
606