IBM System x3650 M4 BD Type 5466 Installation And Service Manual page 456

Table of Contents

Advertisement

806f0607-0301ffff • 806f0607-0302ffff
806f0607-0301ffff
An SM BIOS Uncorrectable CPU complex error for [ProcessorElementName] has asserted.
(CPU 1)
Explanation: This message is for the use case when an SM BIOS Uncorrectable CPU complex error has asserted.
May also be shown as 806f06070301ffff or 0x806f06070301ffff
Severity: Error
Alert Category: Critical - CPU
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0816
SNMP Trap ID: 40
Automatically notify Support: No
User response:
1.
Update the latest level of system firmware and device drivers are installed for all adapters and standard devices,
such as UEFI, IMM Ethernet,and SAS. Important: Some cluster solutions require specific code levels or
coordinated code updates. If the device is part of a cluster solution, verify that the latest level of code is
supported for the cluster solution before you update the code.
2.
Run the DSA program.
3.
(Trained technician only) Replace microprocessor n. (n = microprocessor number)
4.
(Trained technician only) Replace the system board.
806f0607-0302ffff
An SM BIOS Uncorrectable CPU complex error for [ProcessorElementName] has asserted.
(CPU 2)
Explanation: This message is for the use case when an SM BIOS Uncorrectable CPU complex error has asserted.
May also be shown as 806f06070302ffff or 0x806f06070302ffff
Severity: Error
Alert Category: Critical - CPU
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0816
SNMP Trap ID: 40
Automatically notify Support: No
User response:
1.
Update the latest level of system firmware and device drivers are installed for all adapters and standard devices,
such as UEFI, IMM Ethernet,and SAS. Important: Some cluster solutions require specific code levels or
coordinated code updates. If the device is part of a cluster solution, verify that the latest level of code is
supported for the cluster solution before you update the code.
2.
Run the DSA program.
3.
(Trained technician only) Replace microprocessor n. (n = microprocessor number)
4.
(Trained technician only) Replace the system board.
440