80080128-2101ffff
Device [LogicalDeviceElementName] has been added. (Low Security Jmp)
Explanation: This message is for the use case when an implementation has detected a Device was inserted.
May also be shown as 800801282101ffff or 0x800801282101ffff
Severity: Info
Alert Category: System - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0536
SNMP Trap ID:
Automatically notify Support: No
User response: No action; information only.
800b0008-1301ffff
Redundancy [RedundancySetElementName] has been restored. (Power Unit)
Explanation: This message is for the use case when an implementation has detected Redundancy was Restored.
May also be shown as 800b00081301ffff or 0x800b00081301ffff
Severity: Info
Alert Category: Warning - Redundant Power Supply
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0561
SNMP Trap ID: 10
Automatically notify Support: No
User response: No action; information only.
800b0108-1301ffff
Redundancy Lost for [RedundancySetElementName] has asserted. (Power Unit)
Explanation: This message is for the use case when Redundancy Lost has asserted.
May also be shown as 800b01081301ffff or 0x800b01081301ffff
Severity: Error
Alert Category: Critical - Redundant Power Supply
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0802
SNMP Trap ID: 9
Automatically notify Support: No
User response:
1.
Check the LEDs for both power supplies.
2.
Follow the actions in Power-supply LEDs.
80080128-2101ffff • 800b0108-1301ffff
Appendix A. Integrated management module II (IMM2) error messages