IBM System x3650 M4 BD Type 5466 Installation And Service Manual page 363

Table of Contents

Advertisement

8007020f-2201ffff
Sensor [SensorElementName] has transitioned to critical from a less severe state. (TXT ACM
Module)
Explanation: This message is for the use case when an implementation has detected a Sensor transitioned to critical
from less severe.
May also be shown as 8007020f2201ffff or 0x8007020f2201ffff
Severity: Error
Alert Category: Critical - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0522
SNMP Trap ID: 50
Automatically notify Support: No
User response:
1.
If enabling TXT is not required, disable TXT from the Setup Utility.
2.
If enabling TXT is required, verify that the TPM is enabled and activated from the Setup Utility.
3.
If the problem remains, contact your service representative.
8007020f-2582ffff
Sensor [SensorElementName] has transitioned to critical from a less severe state. (No PCI I/O
Space)
Explanation: This message is for the use case when an implementation has detected a Sensor transitioned to critical
from less severe.
May also be shown as 8007020f2582ffff or 0x8007020f2582ffff
Severity: Error
Alert Category: Critical - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0522
SNMP Trap ID: 50
Automatically notify Support: No
User response: Complete the following step to solve PCI I/O resource errors:
1.
Go to F1 Setup
2.
System Settings
3.
Device and I/O ports
4.
PCI 64 bit Resource and choose enable.
8007020f-2201ffff • 8007020f-2582ffff
Appendix A. Integrated management module II (IMM2) error messages
347