Figure 35. ServeRAID adapter installation
Figure 36. ServeRAID adapter installation
7. Connect any required cables to the ServeRAID adapter.
52
System x3650 M4 BD Type 5466: Installation and Service Guide
b. Rotate the retention latch to the close position. Make sure the retention
latch engages the adapter securely.
v For PCI riser-card assembly 2:
a. Pull the release pin to unlock the retention latch; then rotate the retention
latch to the open position.
b. Align the ServeRAID adapter so that the keys align correctly with the
connector on PCI riser-card assembly 2.
c. Insert the ServeRAID adapter into the connector on the riser-card until it
is firmly seated.
Attention: Incomplete insertion might cause damage to the server or the
adapter.