806f060d-0406ffff
Array [ComputerSystemElementName] has failed. (Drive 6)
Explanation: This message is for the use case when an implementation has detected that an Array Failed.
May also be shown as 806f060d0406ffff or 0x806f060d0406ffff
Severity: Error
Alert Category: Critical - Hard Disk drive
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0176
SNMP Trap ID: 5
Automatically notify Support: Yes
User response:
1.
Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2.
Make sure that the SAS cable is connected correctly.
3.
Replace the SAS cable.
4.
Replace the RAID adapter.
5.
Replace the hard disk drive that is indicated by a lit status LED.
806f060d-0407ffff
Array [ComputerSystemElementName] has failed. (Drive 7)
Explanation: This message is for the use case when an implementation has detected that an Array Failed.
May also be shown as 806f060d0407ffff or 0x806f060d0407ffff
Severity: Error
Alert Category: Critical - Hard Disk drive
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0176
SNMP Trap ID: 5
Automatically notify Support: Yes
User response:
1.
Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2.
Make sure that the SAS cable is connected correctly.
3.
Replace the SAS cable.
4.
Replace the RAID adapter.
5.
Replace the hard disk drive that is indicated by a lit status LED.