IBM System x3650 M4 BD Type 5466 Installation And Service Manual page 454

Table of Contents

Advertisement

806f050d-040cffff • 806f050d-040dffff
806f050d-040cffff
Array [ComputerSystemElementName] is in critical condition. (Drive 12)
Explanation: This message is for the use case when an implementation has detected that an Array is Critical.
May also be shown as 806f050d040cffff or 0x806f050d040cffff
Severity: Error
Alert Category: Critical - Hard Disk drive
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0174
SNMP Trap ID: 5
Automatically notify Support: No
User response:
1.
Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2.
Make sure that the SAS cable is connected correctly.
3.
Replace the SAS cable.
4.
Check backplane cable connection.
5.
Replace the RAID adapter.
6.
Replace the hard disk drive that is indicated by a lit status LED.
806f050d-040dffff
Array [ComputerSystemElementName] is in critical condition. (Drive 13)
Explanation: This message is for the use case when an implementation has detected that an Array is Critical.
May also be shown as 806f050d040dffff or 0x806f050d040dffff
Severity: Error
Alert Category: Critical - Hard Disk drive
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0174
SNMP Trap ID: 5
Automatically notify Support: No
User response:
1.
Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2.
Make sure that the SAS cable is connected correctly.
3.
Replace the SAS cable.
4.
Check backplane cable connection.
5.
Replace the RAID adapter.
6.
Replace the hard disk drive that is indicated by a lit status LED.
438
System x3650 M4 BD Type 5466: Installation and Service Guide

Advertisement

Table of Contents
loading

Table of Contents