Operator Panel - IBM 7015-R50 Installation And Service Manual

Cpu enclosure
Hide thumbs Also See for 7015-R50:
Table of Contents

Advertisement

Operator Panel

Removal
1. Depending on the power distribution in your rack, do one of the following:
"Power-Off Procedure with a Power Distribution Bus" on page 4-2
"Power-Off Procedure with a Power Distribution Unit" on page 4-5
"Power-Off Procedure with a Power Distribution Panel" on page 4-9.
2. Do the "Front Bezel and Front Access Plate" removal procedure on page 4-15.
3. Remove the mounting screw attaching the operator panel to the CPU enclosure.
4. Pull the operator panel assembly toward you until it is out of the media module.
Front View of
CPU Enclosure
Operator Panel
Assembly
Replacement
1. Replace in the reverse order.
2. Depending on the power distribution in your rack, do one of the following Power-On
procedures:
"Power-On Procedure with a Power Distribution Bus" on page 4-4.
"Power-On Procedure with a Power Distribution Unit" on page 4-7.
"Power-On Procedure with a Power Distribution Panel" on page 4-11.
4-20
Service Guide
Mounting Screw