IBM 7015-R50 Installation And Service Manual page 236

Cpu enclosure
Hide thumbs Also See for 7015-R50:
Table of Contents

Advertisement

This test consists of two sub-tests. Words manipulated / used are not restored at the end of
the test. This test is applied to all the memory cards which are present. In case of errors,
suitable error messages are displayed on the console. The following is a description of the
sub-tests.
Work Area Test
Main Memory Cards Accessibility Test
If there are any errors in the preceding operations, they are displayed with suitable error
messages on the console.
A-14
Operator Guide
This test calculates the memory address available on each board.
Then the first memory card is accessed and read-write-compare
operation is done for a memory location. If the comparison is OK,
then the test proceeds to check the next board. Otherwise a fatal
error message is displayed on the console.
This test checks whether the high order memory address lines are
open, stuck to level 0, or shorted to any other data line. This is done
in two phases:
First, in Write phase, different patterns are written on the four
memory cards. This is verified to check the accessibility of the
boards.
In the Read phase, the values are read and the interference
between the boards is checked (if the value written for the first
board, appears when the second board is accessed).