Replacement
To replace the vibration isolators when replacing a fan, do the following:
1. Check the direction of the air flow marked on the fan, and then place the long end of the
vibration isolator through the mounting hole of the fan.
2. Pull the long end of the vibration isolator through the mounting hole until the center ring
of the vibration isolator is against the fan.
3. Repeat the two previous steps until all four vibration isolators are mounted on the fan.
4. After all four vibration isolators are mounted on the fan, place the short end of each
vibration isolator through the mounting holes of the fan mounting bracket. If you are
replacing a fan that mounts inside the media module, slide the fan inside the media
module, and then pull each short end of the vibration isolators through the fan mounting
bracket.
5. Pull the short end of each vibration isolator through the mounting holes of the fan
mounting bracket until the center ring of the vibration isolator is against the bracket.
Replace in the reverse order.