IBM 7015-R50 Installation And Service Manual page 266

Cpu enclosure
Hide thumbs Also See for 7015-R50:
Table of Contents

Advertisement

Error
Number
Source
401-591
K
401-592
K
401-593
K
401-594
K
401-595
K
401-800
K
401-801
K
401-802
K
401-803
K
401-804
K
401-805
K
401-806
K
D-8
Service Guide
Failing
Failure
Function
Percent
Codes
(%)
Description
C59
50
Description: Diskette drive access.
C63
25
Error on sense interrupt command.
C61
25
Action: Use MAP 0210.
C59
50
Description: Diskette drive access.
C63
25
Error on write command.
C61
25
Action: Use MAP 0210.
C59
50
Description: Diskette drive access.
C63
25
Error on read command.
C61
25
Action: Use MAP 0210.
C59
50
Description: Diskette drive access.
C63
25
Buffer exchange error.
C61
25
Action: Use MAP 0210.
C59
50
Description: Diskette drive access.
C63
25
Time-out error.
C61
25
Action: Use MAP 0210.
LSA
40
Description: Channel reset and POS.
C59
20
POS3 register error.
C90
20
Action: Use MAP 0210.
C61
10
C63
10
LSA
40
Description: Channel reset and POS.
C59
20
POS4 register error.
C90
20
Action: Use MAP 0210.
C61
10
C63
10
LSA
40
Description: Channel reset and POS.
C59
20
POS2 register error.
C90
20
Action: Use MAP 0210.
C61
10
C63
10
LSA
40
Description: Channel reset and POS.
C59
20
NCR SCRATCH A register error.
C90
20
Action: Use MAP 0210.
C61
10
C63
10
LSA
40
Description: Channel reset and POS.
C59
20
SCSI Bus control lines error.
C90
20
Action: Use MAP 0210.
C61
10
C63
10
LSA
40
Description: Channel reset and POS.
C59
20
Missing ACK signal error.
C90
20
Action: Use MAP 0210.
C61
10
C63
10
LSA
40
Description: Channel reset and POS.
C59
20
Pending ACK signal error.
C90
20
Action: Use MAP 0210.
C61
10
C63
10

Advertisement