Step 4
(from Step 2)
No failure was detected with this configuration.
1. Set the power button on the CPU Enclosure to Off.
2. Unplug both PDB outlet power cords from both power supply power cords.
3. Starting with the CPU cards, install one additional CPU card (CPU) or memory card
(MC) (if any).
4. Plug both PDB outlet power cords into both power supply power cords.
5. Set the power button on the CPU Enclosure to On.
6. Wait for one of the following conditions to occur:
The Maintenance Menu is displayed.
The same three digit number is displayed in the operator panel display for longer than
three minutes except for the number 165 which may display for up to ten minutes with
no activity on the BUMP console.
The number 888 is flashing in the operator panel display.
Is the maintenance menu displayed?
NO
YES
3-1540-6
Service Guide
Go to Step 5.
Repeat Step 4 until all CPU cards (CPU) and all memory cards (MC) are
installed and tested.
After all CPU cards (CPU) and all memory cards (MC) are installed and
tested, set the power button on the CPU Enclosure to Off and unplug both
PDB outlet power cords from both power supply power cords. Do the
following actions.
Install the SCSI adapter.
Connect the SCSI cable from the SCSI adapter to the SCSI connector
located above the disk drive.
Install the terminator on the connector DIFF. SCSI A on the system
interface board (SIB).
Go to Step 7, substep 5.