IBM 7015-R50 Installation And Service Manual page 237

Cpu enclosure
Hide thumbs Also See for 7015-R50:
Table of Contents

Advertisement

Basic Main Memory Test
This test is performed by all the processors and it checks the capability to access the main
memory in all kinds of data formats. This test applies to one main memory location and the
words used during the test are not restored.
This test partially checks the DCB ASICs. It consists of the 10 sub-tests that follow. If an
error is detected in any of these tests, a suitable error message is displayed on the console.
Byte Write Checking
Aligned Half Word Write Checking
Unaligned Half Word Write Checking
Aligned Word Write Checking
Unaligned Word Write Checking
Aligned Double Word Write Checking
Unaligned Double Word Write Checking
Multiple Individual Store Checking
Addressing tests in Work Mode Checking
Aligned Multiple Store Checking
Unaligned Multiple Store Checking
A byte is written and verified. If there is mismatch between the read
value and the written value, an error message is generated.
This test writes a half word and checks for the possible errors in the
read value.
This test writes a half word and checks the corrected value against
the read value.
It writes a full word and checks it against the read value. An error
message is generated if a mismatch is detected between the read
value and the written value.
This test writes an unaligned word and verifies it against the
corrected value.
This test checks the access by writing an aligned double word and
does a read verification. If the verification fails, a console error
message appears.
This test writes an unaligned double word and verifies it against the
corrected value.
Access to the 1MB address is checked through writing. A
comparison is made between written value and the read value.
Access to the 1MB address is checked through writing. A
comparison is made between written value and the read value.
In this test multiple words are written and read back. If the
verification fails, an Aligned Multiple store error is displayed.
This test writes multiple words and checks for misalignment
interrupt. Error message is displayed if it is not set.
A-15
SystemGuard Test Groups

Advertisement

Table of Contents
loading

This manual is also suitable for:

7015-r407015-r30