IBM 7015-R50 Installation And Service Manual page 287

Cpu enclosure
Hide thumbs Also See for 7015-R50:
Table of Contents

Advertisement

Understanding PKSR
The PKSR status is logged in hexadecimal value: 8 digits are logged. Each hexadecimal
digit must be converted in 4 binary digits: 32 bits are obtained. Divide the bits as indicated in
the PKSR layout and check the bit values to understand the meaning of the register.
Example
Suppose you receive an error message whose PKSR content in hex is:
9005 0007
converted to binary:
1001 000 0 0 0 0001 0 1 00000000 0000 0111
0
3 4 6 7 8 9 10 13
This means that the following events occurred:
– fan1 fault
– a warning cooling message is displayed on the console
– the cooling system in operating in backup mode
– the key is in normal position
16
23 24
28 31 = Bit Numbering
Off Line Diagnostic Error Codes