Flags And Parameters Settings - IBM 7015-R50 Installation And Service Manual

Cpu enclosure
Hide thumbs Also See for 7015-R50:
Table of Contents

Advertisement

The configuration of the tty1 for the S2 port looks similar to the following:
[TOP]
TTY
TTY type
TTY interface
Description
Terminal
Status
Location
Parent adapter
PORT number
Enable LOGIN
BAUD rate
PARITY
BITS per character
Number of STOP BITS
TIME before advancing to next port setting [0]
TERMINAL type
FLOW CONTROL to be used
OPEN DISCIPLINE to be used
STTY attributes for RUN time
STTY attributes for LOGIN
[hupcl,cread,echoe,cs8,
LOGGER name
STATUS of device at BOOT time
TRANSMIT buffer count
RECEIVE trigger level
STREAMS modules to be pushed at OPEN time
INPUT map file
OUTPUT map file
CODESET map file

Flags and Parameters Settings

These are the minimum SystemGuard parameters/flags settings required for remote
support. These parameters can be displayed and changed with the mpcfg command.
Modem configuration:
mpcfg –dm
Index
1
2
3
4
5
6
7
8
C-2
Service Guide
Name
Modem Parameters File Name
Service Line Speed
Protocol Inter Data Block Delay
Protocol Time Out
Retry Number
Customer ID
Login ID
Password ID
[Entry Fields]
tty1
tty
rs232
Asynchronous
Available
00–00–S2–00
sa1
[s2]
disable
[9600]
[none]
[8]
[1]
[dumb]
[rts]
[dtropen]
[hupcl,cread,brkint,
icrnl,opost,tab3,
onlcr,isig,icanon,
echo,echoe,echok,
echoctl,echoke,
imaxbel,iexten]
ixon,ixoff]
[]
[available]
[16]
[3]
[ldterm,tioc]
[none]
[none]
[sbcs]
Value
/usr/share/modems/7851
9600
5
60
2

Advertisement