IBM 7015-R50 Installation And Service Manual page 46

Cpu enclosure
Hide thumbs Also See for 7015-R50:
Table of Contents

Advertisement

Stand-By Menu
The STAND-BY MENU can only be entered when the system is in Stand-By mode (the word
Stand-By must be displayed on the LCD display). Perform the following steps to bring up the
STAND-BY MENU.
1. With Stand-By displayed on the LCD display press the Enter key on the BUMP console.
The Stand-By prompt is the greater than (>) sign.
2. To enter the STAND-BY MENU from here, set the System Key into Service mode, either
by setting the Physical Key to Service or the Electronic Key to Service. To set the
Electronic Key to Service, follow the procedure on page 2-39.
3. Press the Enter key again.
4. Enter the keyword sbb to display the STAND-BY MENU.
The STAND-BY MENU appears with several options, as follows:
For Details,
See the
Following
Pages
2-13
2-15
2-16
2-17
2-18
2-19
Note: It is also possible to enter the STAND-BY MENU from the Service Console if the
remote authorization flag is enabled. The Electronic Key can be set from the Service
Console with the same escape sequence.
The STAND-BY MENU allows the system administrator to display the physical configuration
of the system (CPUs, memory, I/O, and so on) and to set flags, such as the Fast IPL flag,
and the BUMP Console Present flag. The Fast IPL flag causes the system to skip the
second phase of the power-on tests. The BUMP Console Present flag allows the BUMP
console to be enabled or disabled during boot up. This menu also enables the service
representative to test the interconnection between the BUMP and different components
through the I2C bus or the SSbus. For instance, it is possible to send a specific string of
characters to the LCD and read the result on the Operator Panel display. Or, it is possible to
turn on the LEDs on the Operator Panel, or to turn on the power supplies and fans without
allowing the system to IPL.
2-12
Service Guide
STAND–BY MENU :
0 Display Configuration
1 Set Flags
2 Set Unit Number
3 Set Configuration
4 SSbus Maintenance
5 I2C Maintenance
Select(x:exit): 0