IBM 7015-R50 Installation And Service Manual page 283

Cpu enclosure
Hide thumbs Also See for 7015-R50:
Table of Contents

Advertisement

Error
Number
Source
409-083
B
409-087
K
409-088
K
409-089
K
409-090
K
C88 or C89
409-091
K
C88 or C89
409-092
K
409-093
E
409-094
E
409-095
E
409-096
E
409-097
E
409-098
K
409-Axy
K
F/W FATAL
K
Firmware
ERROR
Failing
Failure
Function
Percent
Codes
(%)
Description
C60
100
Description: OP microcontroller not working.
Action: Use MAP 0210.
C63
100
Description: MVR not compatible with the CPU boards.
Action: Use MAP 0210.
C63
100
Description: Different cycle time between the present CPU
boards.
Action: Use MAP 0210.
C63
100
Description: Different cycle time between CPU boards and MPB.
Action: Use MAP 0210.
100
Description: No SIF reply on power-on command.
Action: Use MAP 0210.
100
Description: SIF failure status on power-on command.
Action: Use MAP 0210.
C59
100
Description: No valid Flash EPROM/EPROM.
Action: Use MAP 0210.
D19
100
Description: MVR Fan failed.
Action: Use MAP 0210.
D16
100
Description: CPU Fan failed.
Action: Use MAP 0210.
???
100
Description: Disk Fan failed.
Action: Use MAP 0210.
D17
100
Description: MCA Fan failed.
Action: Use MAP 0210.
C92
100
Description: Power Supply failed.
Action: Use MAP 0210.
152
100
Description: Power supply hot.
Action: Use MAP 1540.
152
100
Description: Power supply internal failure.
Action: Use MAP 1520.
100
Description: Firmware Panic: System restart from PON.
Off Line Diagnostic Error Codes