provided stylus to touch the gear icon labelled "B":
000%
RX
TX
RX 00.0V
000:00.0
000
000
mz
000:00.0
0:01:23
Touch
M 1
000
0
NORMAL
Graubele
BATT TIME 00: 01: 23
000
The display switches to the green base menu. Use a
finger or the provided stylus to touch the "Fail Safe"
menu item:
BACK
BASE
FUNCTION
Model Sel
Model Type
E.P.A
Rev/Slow
TX ctl
Fail Safe
Motor
Timer
Touch
Servo
CH Set
Out.Swap
Fail Safe
In comparison to classic PPM technology, the system-
related greater reliability of the HoTT system is because
the microprocessor in the HoTT receiver can process
both undistorted signals from its transmitter as well as
distorted control signals. Only when the signals are
excessively distorted or garbled, for example from noise,
the processor replaces them with control signals that
are saved in the receiver depending on the settings
described below. This allows intermittent disturbances
such as drops in field strength, etc. to be overlooked
which would otherwise lead to familiar "wobbles". When
this occurs, the red LED on the receiver shines during
the interference.
84
Basic menu - Fail safe
When a receiver is delivered, all outputs are
set to "hold" by default. This default can be
individually changed for all receiver outputs
000%
with the assistance of the menu discussed here as well
4.1V
as the "Telemetry" menu, page 118.
BACK
CH
CH 1.
CH 2.
CH 3.
000
CH 4.
Delay
Note:
SYSTEM
In order to set control channels with numbers
higher than CH4, touch
Sub-Trim
Programming
The "Fail Safe" function determines the response of the
Trim Step
receiver when there is an interruption in transmission
from the transmitter to receiver. Receiver outputs
1 ... 9 of the mz-18 HoTT transmitter and 1 ... 12 of
the mz-24 HoTT transmitter can optionally retain their
momentary position...
1. ... ("HOLD").
In case of transmission interruptions, all servos
programmed to "hold" remain at their position which
was last identified as correct until a new, correct
control signal is received by the receiver.
2. ... move to a freely selectable position ("F/S")
after a delay when there is an interruption in the
transmission.
To switch between "HOLD" and "F/S", touch the button
in the "Mode" column in the line of the channel to be
switched to with a finger or the provided stylus, for
example:
Graubele
MODE
SET
HOLD
NEXT
HOLD
STO1
HOLD
STO2
HOLD
0.25s
SET
NEXT
[next page].
BACK
Graubele
CH
MODE
SET
CH 1.
F/S
000%
CH 2.
HOLD
CH 3.
HOLD
CH 4.
F/S
000%
Delay
0.25s
After switching to "F/S", in the "SET" column touch,
with a finger or the provided stylus, one of the value
fields that appears upon switching to "F/S" such as the
value field that appears in the "CH1" line:
BACK
Graubele
MODE
CH
SET
CH 1.
F/S
000%
CH 2.
HOLD
Touch
CH 3.
HOLD
CH 4.
F/S
000%
Delay
0.25s
The color of the field switches from red to blue:
BACK
Graubele
CH
MODE
SET
CH 1.
F/S
000%
CH 2.
HOLD
CH 3.
HOLD
CH 4.
F/S
000%
Delay
0.25s
Move the control element for this control channel into
the desired position and, with a finger or the provided
stylus, touch the
button at the bottom right of the
SET
display to transfer the position into the value field, for
example:
NEXT
STO1
STO2
SET
NEXT
STO1
STO2
SET
NEXT
STO1
STO2
SET