Motor (electric motor)

Throttle Cut (gas engine)

Switchable throttle cut or motor limiter
Note:
This menu is hidden when selecting a model
configuration "NO POWER" in the basic
settings of the "Model Sel" or "Model
type" menu.
In the basic transmitter display, use a finger or the
provided stylus to touch the gear icon labelled "B":
000%
RX
TX
RX 00.0V
000:00.0
000
000
mz
000:00.0
0:01:23
Touch
M 1
000
0
NORMAL
Graubele
BATT TIME 00: 01: 23
000
The display switches to the green base menu. Touch
the menu item "Motor" (airplane or glider with electric
motor) or "Throttle Cut" (helicopter with electric or gas
engine and airplane with gas engine) with a finger or the
provided stylus.
BACK
BASE
FUNCTION
Model Sel
Model Type
E.P.A
Rev/Slow
Motor
TX ctl
Timer
Fail Safe
Touch
CH Set
Out.Swap
NOTE:
"Motor" is working over the complete range
(-100 to +100 % CH1 control stick position)
and "Throttle Cut" is only working, when CH1
control stick position is below -66 %.
72
Basic menu - Motor / THR.CUT
BACK
Model Sel
THR.CUT
000%
Touch
4.1V
Motor / Throttle Cut
In the "Motor" or "Throttle Cut" menu, you can switch
off a speed controller by a switch, or move a servo for
the throttle control into motor OFF position (or to idle
position). This option can also be used as an emergency
Cut OFF function as well. The motor OFF position, or for
example an idle position, is designated in the value field
000
of the "SET" line and needs to be determined through
experimentation.
The speed controller or the throttle servo only assumes
the set position after a switch has been activated and
the switching threshold in the "SET" line is undershot by
the CH1 control stick.
If the set percentage in the "SET" line is greater
SYSTEM
than the current Ch1 control stick position, that is,
the current position represented by the green arrow
to the left of the bar graph is below the switching
Sub-Trim
threshold, switching occurs when the switch is in the
ON position.
Trim Step
If the set percentage in the "SET" line is less than
the current CH1 control stick position, that is, the
current servo position represented by the green
arrow to the left of the bar graph is above the
switching threshold, the speed controller reduces
the motor speed, or the throttle servo closes the
carburettor as specified in the "SET" line once the
CH1 control stick position falls below the switching
threshold when the switch is in the ON position.
In this motor OFF position, the speed controller or
throttle servo are disabled until the selected switch
BASE
FUNCTION
SYSTEM
Model Type
E.P.A
Rev/S ow
Sub-Trim
TX ctl
Timer
Fail Safe
Trim Step
CH Set
Out.Swap
is switched. The throttle servo or speed controller is
then moved beyond the preprogrammed switching
threshold with the Throttle/brake control stick.
A threshold of -100% the servo position is the default in
the value field of the "SET" line:
NORMAL
BACK
Graubele
ACT
INH
CTL
ON
SET
–100%
Programming
To change the default for the switching threshold or
"Motor OFF" position, touch the value field in the "SET"
line with a finger or the provided stylus:
NORMAL
BACK
Graubele
ACT
INH
Touch
CTL
O
SET
–100%
The color of the field switches from red to blue:
NORMAL
BACK
Graubele
ACT
INH
CTL
ON
SET
–100%
S
INC
RES
DEC
S
INC
RES
DEC
S
INC
RES
DEC