CH OUTPUT TYPE
In this line, select the type of servo control or alternately
the signal type of the aggregate signal output:
ONCE
BACK
Graubele
RX SERVO TEST
<
ALL-MAX
: 2000µsec
ALL-MIN
: 1200µsec
TEST
: STOP
ALARM VOLT : 3:8V
ALARM TEMP+: 55°C
ALARM TEMP–:–10°C
>CH OUT
TYPE:ONCE
The servo connectors of the receiver are actuated
sequentially. Recommended for analogue servos.
With this setting, the servos are automatically
operated at a cycle of 20 ms (30 ms for a 12 channel
GR-24 receiver (order No. 33512)) no matter what
is set or displayed in the "RX SERVO" display in the
line "PERIOD".
SAME
BACK
Graubele
RX SERVO TEST
<
ALL-MAX
: 2000µsec
ALL-MIN
: 1200µsec
TEST
: STOP
ALARM VOLT : 3:8V
ALARM TEMP+: 55°C
ALARM TEMP–:–10°C
>CH OUT
TYPE:SAME
The servo connectors of the receiver are actuated
simultaneously in blocks. That is, the servos
connected to connectors 1 to 4 as well as 5 to 8 can
be simultaneously supplied with their control signals
with a GR-16 receiver (order No. 33508), and the
servos connected to connectors 1 to 4, 5 to 8 as
well as 9 to 12 can be simultaneously supplied with
their control signals with a GR-24 receiver (order No.
(connection type)
33512).
This is recommended for digital servos when several
servos are used for a single function (such as an
aileron) so that the servos are fully synchronized.
When exclusively digital servos are used, it is
recommendable to set "10 ms" in the line "PERIOD"
of the display "RX SERVO" to exploit the fast reaction
RECV
ESC
of digital servos. When analogue servos or mixed
GENE
DEC
operation is used, be sure to select "20 ms".
ELEC
INC
When this setting is used, make sure
VARIO
ENT
that the receiver power supply is
sufficiently large. Since four servos are
GPS
SET
always triggered simultaneously when "SAME" is
ESC
selected, the power supply is subjected to a greater
load.
SUMO
A HoTT receiver configured as SUMO always
generates an aggregate signal from the control
signals of all its controls channels, and forwards this
to servo connector 8 of the GR-24 receiver (order
No. 33512) which comes standard with the sets.
With receivers that have a two-digit number to the
right of "SUMO" in their display, ...
BACK
RECV
ESC
RX SERVO TEST
GENE
DEC
ALL-MAX
ELEC
INC
ALL-MIN
TEST
VARIO
ENT
ALARM VOLT : 3:8V
GPS
SET
ALARM TEMP+: 55°C
ALARM TEMP–:–10°C
ESC
>CH OUT
... the active field switches to the right to channel
selection by touching the
right after "SUMO" is confirmed. With the selection,
you determine the highest control channels within
the SUMO signal.
(aggregate signal OUT)
Graubele
RECV
ESC
<
: 2000µsec
GENE
DEC
: 1200µsec
: STOP
ELEC
INC
VARIO
ENT
GPS
SET
TYPE:SUMO
08
ESC
button at the bottom
SET
Function menu - Telemetry | SETTING & DATA VIEW
BACK
Graubele
RECV
RX SERVO TEST
<
ALL-MAX
: 2000µsec
GENE
ALL-MIN
: 1200µsec
TEST
: STOP
ELEC
ALARM VOLT : 3:8V
VARIO
ALARM TEMP+: 55°C
GPS
ALARM TEMP–:–10°C
>CH OUT TYPE:SUMO
08
ESC
You can confirm this setting by again touching
the
button at the bottom right, or use the
SET
or
buttons to select one of the other channels
DEC
between 04 and 09 or 12 and confirm it with
The receiver outputs 1 ... 8 and possibly 9 and
higher are sequentially actuated in a 20 ms cycle
(30 ms with the GR-32 DUAL receiver, order No.
33516), even when 10 ms is set on the display
page "RX SERVO" in the line "PERIOD", and the
corresponding aggregate signal is sent to servo
output 8.
Primarily conceived for the satellite operation
(described below) of two HoTT receivers, the
aggregate signal that is generated by the receiver
and defined as a SUMO can also be used to control
a flybar system, providing that it has an appropriate
input, or it can be used to control flight simulators by
means of the adapter cable (order No. 33310).
In ...
satellite mode
... two HoTT receivers are connected to each other
by means of a three-wire connecting cable (order
No. 33700.1 (300 mm) or 33700.2 (100 mm)) to servo
connectors for specific receiver types. Type GR-16
receivers (order No. 33508) and GR-24 (order No.
33512) are for example connected to each other at
servo output 8. Type GR-32 DUAL receivers (order
No. 33516) contrastingly have their own aggregate
signal connector at the bottom left identified with
"- + S". Further information can be found on the
ESC
DEC
INC
ENT
SET
INC
.
SET
125