Reverse/Slow

Setting the servo rotational direction and delay
In the basic transmitter display, use a finger or the
provided stylus to touch the gear icon labelled "B":
000%
RX
TX
RX 00.0V
000:00.0
000
000
mz
000:00.0
0:01:23
Touch
M 1
000
0
NORMAL
Graubele
BATT TIME 00: 01: 23
000
The display switches to the green base menu. Touch
the menu item "Rev/Slow" with a finger or the provided
stylus.
BACK
BASE
FUNCTION
Model Sel
Model Type
E.P.A
Rev/Slow
Touch
TX ctl
Fail Safe
Motor
Timer
Servo
CH Set
Out.Swap
Servo direction of rotation and control delay
NORMAL
BACK
Graubele
1.
NOR
0.0s
7.
NOR
0.0s
2.
NOR
0.0s
8.
NOR
0.0s
3.
NOR
0.0s
9.
NOR
0.0s
4.
NOR
0.0s
10.
NOR
0.0s
5.
NOR
0.0s
11.
NOR
0.0s
.6
NOR
0.0s
12.
NOR
0.0s
In this display, exclusively the direction of rotation
relating to the respective servo is set in the left column.
In contrast, a delay is entered in the right column for the
control function corresponding to the selected channel.
68
Basic menu - Servo reverse/servo delay
Note:
In contrast to the display of the 12-channel
mz-24 HoTT transmitter in this section,
000%
4.1V
only channels 1 ... 9 are offered in the
display of the 9-channel mz-18 HoTT transmitter.
If you have created Quick Links in the submenu
"Q.Link" (page 132 or 168) and have assigned an
appropriate name, it appears at the top right such as
"NORMAL" as shown.
However, the settings in the left column,
"direction of servo rotation", have a global
000
effect. Only the delays may be set for the
specific Quick Links in the right column, "Delay".
When setting the delays, activate the wanted Quick
Link by operating its corresponding switch.
SYSTEM
Setting the rotational direction of the servos is
independent of the Quick Link
Important:
Sub-Trim
The numbers for the servos refer to to the
servos connected to the corresponding
Trim Step
receiver outputs providing that the
transmitter and receiver outputs have not been
swapped. A change in the control mode therefore
does not influence the numbering of the servos.
With this option, the direction of servo rotation is
adapted to the specifics in the particular model
S
independent of the Quick Link so that, when the
control linkages and articulations are installed, the
servo's rotational direction does not have to be
considered.
INC
The servo's rotational direction should be
RES
determined before the servo travel is set.
DEC
The direction of travel is reversed by touch-
ing the corresponding value fields labelled
and
, such as:
REV
BACK
Graubele
1.
NOR
0.0s
2.
REV
0.0s
3.
NOR
0.0s
4.
NOR
0.0s
5.
REV
0.0s
.6
NOR
0.0s
Note:
As of firmware version V1.020, a warning
was inserted which appears when an
attempt is made to change the direction of
travel of CH1:
Touch
BAC
Graubele
1.
NOR
0.0s
2.
REV
3.
NOR
4.
NOR
5.
REV
0.0s
.6
NOR
0.0s
Touch
NO
with a finger or the provided stylus to
terminate the procedure. Touch
procedure which changes the direction of travel of
the servo connected to CH1.
NOR
NORMAL
S
7.
NOR
0.0s
8.
NOR
0.0s
9.
NOR
0.0s
INC
10.
NOR
0.0s
RES
11.
NOR
0.0s
DEC
12.
NOR
0.0s
NORMAL
S
7.
NOR
0.0s
Warning
s
Are you sure?
s
INC
YES
NO
s
RES
11.
NOR
0.0s
DEC
12.
NOR
0.0s
YES
to confirm the

Advertisement