Important instructions:
The transmitter which comes with the
set comes with the correct operating
settings for most countries in Europe.
However in this context, please also note the in-
structions on page 76.
Using connectors 1 ... 9, a maximum of 9 servos
can be operated with the mz-18 HoTT transmit-
ter together with the GR-24 receiver which comes
with the set and is already linked to the first mod-
el memory. Any servos which are connected to
connectors 10 - 12 remain in their middle posi-
tion by default and cannot be actuated by the
transmitter.
A maximum of 12 servos can be operated with
the mz-24 HoTT transmitter together with the GR-
24 receiver which comes with the set and is al-
ready linked to the first model memory.
For the sake of maximum flexibility and to
prevent unintentional misuse, control channels
5-9 and 5-12 are initially not assigned to any
control elements, and the servos linked to these
channels first remain in their middle position
until an operating element has been assigned.
For the same reason, nearly all mixers are
inactive. More information on this subject can be
found on page 92.
The basic procedure for initially programming a
new model memory starts on page 45.
When training, linking or adjusting the remote
control, make sure that the transmitter antenna
is always far enough from the receiver antennas.
If the transmitter antenna is too close to the
receiver antennas, the receiver will overamplify
the receiver, and the red LED on the receiver will
shine. At the same time, the feedback channel
will stop working, the field strength bar in the
transmitter display will disappear, and the
current receiver battery voltage will be displayed
as 0.0 V. The remote control is simultaneously in
fail safe mode (see page 84). That is, due to the
loss of reception, the servos remain in the last
correctly received or fail safe positions until a
new valid signal is received. In this case, move
away until the displays return to normal.
WARNING:
Never switch off the transmitter while
operating the model! If this nonetheless
accidentally happens, do not panic, and
wait until the transmitter display goes dark which
indicates that the transmitter is completely off. This
will take at least four seconds. After this time,
switch on the transmitter again. Otherwise, the
transmitter may freeze directly after being switched
on, and you will be unable to control the model. The
transmitter may only be switched on again after it
has been switched off and the described procedure
has been correctly repeated.