NORMAL
BACK
Graubele
FLAP1
FLAP3 FLAP4
FLAP2
RATE A
+100%
+100%
000%
000%
RATE B
+100%
000%
000%
+100%
OFFSET
000%
000%
000%
000%
Then, in the active (blue) value field, press
increase the current value within a range of ±125%
and
to reduce it, for example:
DEC
NORMAL
BACK
Graubele
FLAP1
FLAP3 FLAP4
FLAP2
+025%
RATE A
000%
000%
+100%
RATE B
+100%
000%
000%
+100%
OFFSET
000%
000%
000%
000%
Use the same procedure with value for the downward
deflection of the left flap (RATE B) and for the
values of the right flap and for any second flap pair.
Symmetrical and asymmetrical values are possible.
"Offset" line
In this line, set the Q.Link-specific positions for all
of the flaps in the respective model. This allows you
to set the positions that the individual flaps are to
assume for each Q.Link.
The adjustment range of ±100% allows the flaps to
be moved to the desired position independent of the
rotational direction of the flap servos, for example:
S
BACK
INC
FLAP1
RES
+100%
RATE A
DEC
RATE B
+100%
OFFSET
+033%
to
INC
Note:
The available setting options depend on
the number of flaps selected in the
S
"Model Sel" or "Model Type" menu.
The flap offset value set here is transferred to the
Quick Link trim described in the following section,
"Flap Sett".
INC
Set the Quick Link-specific flap positions of the
RES
aileron in the mz-18 HoTT transmitter in the display
"CH 5-9" or in the mz-24 HoTT transmitter in the
DEC
display "CH 5-12" of the respective "D/R,EXP" menu,
starting on page 136, in line "CH5" such as in the
Quick Link "THERMAL":
BACK
+020%
CH5
000%
CH6
000%
CH7
000%
CH8
OFFSET
Note:
In contrast to the above display of the
12-channel mz-24 HoTT transmitter, only
channels 1 ... 9 are offered in the display
of the 9-channel mz-18 HoTT transmitter.
NORMAL
S
Graubele
FLAP3 FLAP4
FLAP2
INC
+100%
RES
+100%
+100%
+100%
+100%
+100%
DEC
+055% +055%
+033%
THERMAL
S
Graubele
CH
CH5-12 CTL
000%
CH9
000%
INC
CH10
RES
000%
CH11
000%
DEC
CH12
OFFSET
Touch the
button to reset a changed value in the
RES
blue (and hence active) field to the default.
After you have finished making your settings, touch
the
button at the top left to return to the mixer
BACK
selection:
THERMAL
BACK
Graubele
FLAP-TYPE
ACT
SET
CTL
>>
FLAP
>>
AILE >> FLAP
INH
ON
ELEV >> FLAP
INH
>>
ON
>>
FLAP >> ELEV
INH
ON
AILE >> FLAP line
In this line, you can set for each Quick Link the amount
of movement of the flap pair "FLAP" (and possibly
"FLAP2") as an aileron when the aileron is actuated.
Normally, the flaps follow the ailerons with less
deflection, that is, the mixed amount is less than 100%.
The setting range of ±125 % makes it possible to
appropriately adapt the direction of deflection to the
ailerons depending on the direction of rotation of the
flap servos.
Since all values are set separately, the aileron
deflections of the flaps can also be different.
Adapt the individual values as described above, for
example:
THERMAL
BACK
Graubele
AILE >> FLAP
CTL
ON
FLAP1
FLAP3 FLAP4
FLAP2
RATE A
+055%
+033%
+033%
+055%
RATE B
+055%
+033%
+033%
+055%
Airplane model function menu - Flap MIX
S
S
INC
RES
DEC
153