GRAUPNER S1005 Programming Manual page 154

Hide thumbs Also See for S1005:
Table of Contents

Advertisement

Note:
The available setting options depend on the
number of flaps selected in the "Model Sel" or
"Model Type" menu.
After you have finished making your settings, touch
the
button at the top left to return to the mixer
BACK
selection:
NORMAL
BACK
Graubele
FLAP-TYPE
ACT
SET
CTL
>>
FLAP
>>
AILE >> FLAP
INH
ELEV >> FLAP
INH
>>
>>
FLAP >> ELEV
INH
ELEV >> FLAP line
To support the elevator in tight curves and aerobatics,
the flap function can be included by controlling the
elevator with this mixer. Select the mixing direction so
that the flaps move downward when the elevator is
pulled (up), and conversely upward when the elevator is
pushed (down), that is, in an opposite direction.
A symmetrical or an asymmetrical effect can be defined
for each flap pair. Values of ±125% are possible. By
default, uniform values of +30% are set for the aileron ...
SPEED
BACK
Graubele
ELEV >> FLAP
CTL
ON
AILE1
AILE2
AILE3 AILE4
RATE A
+030%
+030%
+030%
+030%
RATE B
+030%
+030%
+030%
+030%
... and the flaps:
154
Airplane model function menu - Flap MIX
BACK
ELEV >> FLAP
RATE A
RATE B
S
Adapt the individual values as described under "FLAP
line".
ON
Note:
ON
The available setting options depend on the
ON
number of flaps selected in the "Model Sel" or
"Model Type" menu.
After you have finished making your settings, touch
the
button at the top left to return to the mixer
BACK
selection:
BACK
FLAP-TYPE
FLAP
AILE >> FLAP
ELEV >> FLAP
FLAP >> ELEV
S
FLAP >> ELEV line
When setting flaps, upward or downward torque can
arise about the transverse axis. It may also be desirable
INC
for the model to pick up the pace somewhat when
RES
slightly elevating the flaps. Both of these reactions can
DEC
be achieved with the mixer.
When setting the flaps, you can use this mixer to
have the position of the aileron automatically track the
flaps depending on the set value. The setting can be
symmetrical or asymmetrical to the neutral point of the
SPEED
S
Graubele
CTL
ON
FLAP1
FLAP3 FLAP4
FLAP2
INC
+030%
+030%
RES
+030%
+030%
+030%
+030%
+030%
+030%
DEC
SPEED
Graubele
S
ACT
SET
CTL
>>
>>
INH
ON
>>
INH
ON
>>
INH
ON
flap control.
The adjustment range is ±125%. With this mixer, normal
settings lie within the single-digit to low double -digit
range. By default, 0% is uniformly set:
SPEED
BACK
Graubele
ELEV >> FLAP
CTL
ON
ELEV
RATE A
000%
RATE B
000%
Adapt the individual values as described at the
beginning of this section under "FLAP line".
After you have finished making your settings, touch
the
button at the top left to return to the mixer
BACK
selection:
SPEED
BACK
Graubele
FLAP-TYPE
ACT
SET
CTL
>>
FLAP
>>
AILE >> FLAP
INH
>>
ELEV >> FLAP
INH
FLAP >> ELEV
INH
>>
After you have finished making your settings, touch
the
button at the top left of the display to return
BACK
to the menu selection:
S
NEXT
INC
RES
DEC
S
ON
ON
ON

Advertisement

Table of Contents
loading

This manual is also suitable for:

S1006

Table of Contents