Microflex Wireless Specifications

System

RF Carrier Frequency Range
Band
Region
Z10
USA, Canada, Mexico
Europe, Asia,
Z11
Middle-East
Z12
Japan
Z15
Taiwan
Z14
Brazil
Working Range
50 m (160 ft)
Note: Actual range depends on RF power setting, signal
absorption, reflection, and interference.
Audio Frequency Response
50 Hz – 20 kHz (+1, -3 dB)
Note: Dependent on microphone type
Dynamic Range
>99 dB, A-weighted
System Gain
Mic gain @ 0dB to line level output on MXWANI through
Dante
+50 dB
Latency
18 ms, nominal
97
System Audio Polarity
Frequency Range
1920–1930 MHz
1880–1900 MHz
Radio Transmission
1893–1905 MHz
1880–1895 MHz
RF Sensitivity
1910–1920 MHz
Power
Cable Requirements
Network Addressing Capability
Operating Temperature Range
Storage Temperature Range
Positive pressure on microphone diaphragm (or positive
voltage on pin 3 of TA4M connector) produces a positive
voltage on pin 2 of the ANI (with respect to pin 3 of the
low-impedance output).
Time Division Multiple Access (TDMA), Gaussian
Frequency Shift Keying (GFSK), 365 kHz max. deviation
−87 dBm, minimum
19 dBm (80 mW) maximum, See Frequency Range and
Output Power table
Cat 5e or higher, shielded, 100 m maximum between
network devices
DHCP, link-local, static
0°C (32°F) to 49°C (120°F)
-29°C (-20°F) to 74°C (165°F)