To Connect The Cables; Installing Cables On The Back Of The Option 11C Mini Cabinet - Nortel CallPilot 201i Hardware Installation

Callpilot release 4.0
Hide thumbs Also See for Nortel CallPilot 201i:
Table of Contents

Advertisement

Installing the 201i server in an Option 11C or Option 11C Mini
Installing cables on the back of the
Option 11C Mini cabinet
Introduction
The following items connect to the back of the Option 11C Mini cabinet:
multi I/O cable (NTRH0912)
Option 11C Mini power cord with two ferrites
You must connect the multi I/O cable first before connecting the power
cord, because the power cord routes over the multi I/O cable connection.

To connect the cables

1 On the rear of the Option 11C Mini cabinet, locate the connector
associated with the first slot occupied by the 201i server.
2 Connect the NTRH0912 multi I/O cable as follows:
a. Loosen the connector's Velcro fastening strap.
b. Connect the amphenol connector on the NTRH0912 multi I/O cable to
the connector on the back of the Option 11C Mini cabinet.
c. Secure the connection by tightening the retaining screw and Velcro
fastening strap of the connector.
92
Standard 1.07
CallPilot