Nortel CallPilot 201i Hardware Installation
Nortel CallPilot 201i Hardware Installation

Nortel CallPilot 201i Hardware Installation

Hide thumbs Also See for CallPilot 201i:
Table of Contents

Advertisement

Nortel CallPilot
201i Server Hardware Installation
ATTENTION
Clicking on a PDF hyperlink takes you to the appropriate page. If necessary,
scroll up or down the page to see the beginning of the referenced section.
NN44200-301
.

Advertisement

Table of Contents
loading

Summary of Contents for Nortel CallPilot 201i

  • Page 1 Nortel CallPilot 201i Server Hardware Installation ATTENTION Clicking on a PDF hyperlink takes you to the appropriate page. If necessary, scroll up or down the page to see the beginning of the referenced section. NN44200-301...
  • Page 2 The process of transmitting data and call messaging between the CallPilot server and the switch or system is proprietary to Nortel Networks. Any other use of the data and the transmission process is a violation of the user license unless specifically authorized in writing by Nortel Networks prior to such use. Violations of the license by alternative usage of any portion of this process or the related hardware constitutes grounds for an immediate termination of the license and Nortel Networks reserves the right to seek all allowable remedies for such breach.
  • Page 3 QUICKTIME is a trademark of Apple Computer, Inc. RADISYS is a trademark of Radisys Corporation. ROLM is a trademark of Siemens ROLM Communications Inc. SLR4, SLR5, and TANDBERG are trademarks of Tandberg Data ASA. SONY is a trademark of Sony Corporation. SYBASE is a trademark of Sybase, Inc.
  • Page 5 Publication History February 2007 CallPilot 5.0, Standard 01.01 of the CallPilot 201i Server Hardware Installation guide is issued for general release. Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 6 6 Publication History Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 7: Table Of Contents

    Communication Server 1000 description 71 Removing the Media Gateway or Media Gateway Expansion cover 75 Installing the 201i server 77 Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 8 Installing the MPCs 102 Installing the monitor, keyboard, and mouse 104 Connecting the CD-ROM and tape drives 105 Connecting the 201i server to the switch, ELAN subnet , and Nortel server subnet 113 Connecting the modem 116 Completing the installation 118...
  • Page 9: Chapter 1 How To Get Help

    Getting help over the phone from a Nortel Solutions Center If you don’t find the information you require on the Nortel Technical Support Web site, and have a Nortel support contract, you can also get help over the phone from a Nortel Solutions Center.
  • Page 10 To access some Nortel Technical Solutions Centers, you can use an Express Routing Code (ERC) to quickly route your call to a specialist in your Nortel product or service. To locate the ERC for your product or service, go to: http://www.nortel.com/erc...
  • Page 11: Chapter 2 About The 201I Server

    Introduction The 201i server is a flexible multimedia telephony server designed to integrate with Nortel Meridian 1* and Communication Server* 1000 products. The 201i server occupies two slots of a Meridian 1 shelf or Communication Server 1000 Media Gateway or Media Gateway Expansion. When the server is locked into position, its connectors attach to the backplane, which provides power and communications links.
  • Page 12 12 Chapter 2 About the 201i server Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 13 Two Ethernet controllers on the 201i server motherboard provide Ethernet capability. These controllers provide the network interfaces for both the ELAN subnet and the Nortel server subnet. The connections to these subnets are established by using the multi I/O cable described on "Multi I/O...
  • Page 14 The following diagram shows the 201i server faceplate. The faceplate provides LEDs, MPC card slots, and connectors for peripheral devices: Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 15 Expansion. Keyboard connector The keyboard connector is a standard PS/2 connector and is hot-pluggable. Infrared port For future use. Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 16 Press the button to eject the card from its slot. Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 17 Press the reset button while the operating system is running only when you cannot shut down the operating system normally. Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 18: Network Connectivity

    Meridian 1 switches: • large systems, such as Option 51C • Option 11C • Option 11C Mini Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 19 The following diagram shows an example of how the 201i server can be integrated with the Communication Server 1000 system in your network: Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 20 Note: For more information about the ELAN subnet, see the CallPilot Installation and Configuration Task List. You use the 201i server multi I/O cable to establish the connections to the ELAN subnet and the Nortel server subnet. For more information, see "Multi I/O cable description" (page 21).
  • Page 21 Meridian 1 or Communication Server 1000 Media Gateway or Media Gateway Expansion backplane, ELAN and CLAN Ethernet hubs or switches, and modem. Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 22: Peripheral Connectivity

    Peripheral connectivity Introduction Peripheral equipment is attached to the 201i server on the server faceplate. Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 23 Option 11C Mini" (page 63). • Communication Server 1000: "Installing the NTRH3502 SCSI cable for Communication Server 1000" (page 80). Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 24 201i server and the Meridian 1 switch or Communication Server 1000 system. Since the hub or switch is an external device, it requires an AC power source. Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 25 Note: The mouse connector on the 201i faceplate is a PS/2 connector. If you plan to use a USB mouse with USB-to-PS/2 converter, you must also use the Nortel-supplied 101 mm (4-in) PS/2 extension cable (A0855616). Without the extension cable, the monitor connector partially blocks the mouse connector.
  • Page 26 26 Chapter 2 About the 201i server Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 27: Chapter 3 Preparing For Installation

    For more information, refer to Chapter 2, "Grounding and power requirements", in the CallPilot Planning and Engineering Guide. Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 28 "Unpacking and inspecting the 201i server" (page 31)). Familiarize yourself with the "Switch and network requirements" (page 33) of this guide. Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 29 SCSI cable for Communication Server 1000" (page 80) Set the DIP switches on the modem (see "Setting the modem DIP switches" (page 90)). Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 30 Connect the multi I/O cable to the ELAN and CLAN Ethernet hubs or switches (see "Connecting the 201i server to the switch, ELAN subnet , and Nortel server subnet" (page 113)). Note: If more than 3 m (10 ft) of multi I/O cable is required, use the supplied RJ-45 female-to-female gender change jacks to attach additional cable.
  • Page 31: Unpacking And Inspecting The 201I Server

    201i server for damage It also describes what to do if you determine that the 201i server is faulty. Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 32 Item Are all cables securely seated? • hard drive power cable • hard drive data cable Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 33: Switch And Network Requirements

    See 201i server components diagram on page 15. What to do if components are missing or damaged THEN you observe any damage contact your Nortel technical support representative. components have become loose secure them. If necessary, refer to the procedures in the CallPilot <server model>...
  • Page 34 The other connection is for the external SCSI device. This connection corresponds to the right slot (when viewing the front of the Meridian 1 switch). Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 35 The ELAN subnet and the Nortel server subnet must be configured and the appropriate networking equipment must be available. If the Nortel server subnet is to be part of the customer LAN, you need a network specialist to ensure proper configuration.
  • Page 36 36 Chapter 3 Preparing for installation Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 37: Chapter 4 Installing The 201I Server In A Large Meridian

    I/O panel on the rear of the switch, as follows: • One connection is for the multi I/O cable. Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 38 Backplane (tip and ring) cable The backplane (tip and ring) cable supplied with the 201i server (NTRH3501) provides 100Base-T Ethernet operation for the Nortel server subnet. This cable offers more network throughput than the cable that is already installed on the Meridian 1.
  • Page 39: Repositioning The Secondary Backplane Connector

    Meridian 1 spacing. The inside pair provides the Option 11C or Option 11C Mini spacing. See the following diagram: Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 40 Replace and alternately tighten all screws until the connector is evenly and securely fastened. Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 41 Replace the pin connector so the pins protrude through both connectors. Ensure that the connectors are correctly aligned as shown in the diagram below. Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 42: Installing The 201I Server In The Large Meridian 1 Switch

    The 201i server occupies two slots. You can install the 201i server in slots 0 through 14. Ensure that both slots have electrical backplane connectivity. Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 43: Removing The Backplane (Tip And Ring) Cables

    Meridian 1. This cable is connected to the backplane connectors and I/O panel slot associated with the left slot. • NTRH1408 intermediate SCSI cable Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 44 Remove the I/O panel cover from the rear of the Meridian 1 switch. Remove the protective plate from the rear of the Meridian 1 switch. Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 45 Retain the mounting hardware (that is, screws, tie wrap base, standoffs, and so on). You will reuse this hardware to fasten the NTRH3501 cable. Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 46 The following diagram shows an example using slots 3 and 4: —End— What is next? Continue with "Installing the NTRH3501 backplane cable" (page 47). Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 47: Installing The Ntrh3501 Backplane Cable

    Introduction You must connect the backplane (tip and ring) cable supplied with the 201i server (NTRH3501) for 100Base-T Ethernet operation to the Nortel server subnet. This cable offers more network throughput than the cable you just removed from the Meridian 1.
  • Page 48 Connect the 50-pin amphenol connector on the multi I/O cable (NTRH0912) to the NTRH3501 backplane cable connector on the I/O panel. —End— See the following diagram: Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 49: Installing The Scsi Cables For Meridian 1 49

    CAUTION Risk of equipment damage You must power off the 201i server before connecting or disconnecting SCSI cables. Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 50 Meridian 1. In this diagram, the CD-ROM drive is the first device. The tape drive is the last device. Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 51 You will connect it later to the 201i server faceplate. Note: The following diagram shows what the connection looks like after the cable is connected: Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 52 201i server right slot. Connect the NTRH1410 cable to the NTRH1408 cable connector on the I/O panel. See the following diagram: Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 53 Prepare the modem, CD-ROM drive, and tape drive for connection to the 201i server. For instructions, see Chapter 7 "Preparing peripheral devices" (page 89). Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 54 54 Chapter 4 Installing the 201i server in a large Meridian 1 system Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 55: Chapter 5 Installing The 201I Server In An Option 11C Or Option 11C Mini

    0 or 4, because these slots are dedicated to other cards. For more information about cards and slots, refer to the Option 11C Mini documentation. Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 56 Ensure that no cables are connected to the slots in which you are installing the 201i server. Open the lock latches at the top and bottom of the 201i server faceplate. Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 57 The 201i server receives power and starts as soon as the 201i server makes contact with the switch backplane. Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 58: Section A: Installing Option 11C Cables

    The CD-ROM or tape drive connects to this bracket assembly with the NTRH3502 cable that is provided with the device. Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 59 Option 11C. The CD-ROM drive is the first device. The tape drive is the last device. Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 60 Attach the bracket assembly and cable as follows: a. Below the card cage, temporarily remove the hardware that secures cable connections to the Option 11C. Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 61 Option 11C cabinet. See the following diagram: Thread the cable up through the card cage. Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 62 Replace all cabling and hardware that you removed in Step Restore any services that you took out of service in Step —End— Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 63: Section B: Installing Option 11C Mini Cables

    Option 11C Mini. In the diagram, the CD-ROM drive is the first device. The tape drive is the last device. Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 64 If your Option 11C Mini is equipped with a Fiber Routing Guide, temporarily remove it. Note: For detailed instructions, refer to the Option 11C and Option 11C Mini Expansion Guide Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 65 See the following diagram: Remove the inner SCSI bracket from the inside of the cabinet. See the following diagram: Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 66 Fasten the SCSI cable drain wire to the top screw that previously held the inner SCSI bracket in place. Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 67 Note: For detailed instructions, refer to the Option 11C and Option 11C Mini Expansion Guide See the following diagram: Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 68: Installing Cables On The Back Of The Option 11C Mini Cabinet

    You must connect the multi I/O cable first before connecting the power cord, because the power cord routes over the multi I/O cable connection. Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 69 See the diagram in step 4. Connect the power cord to the Option 11C Mini cabinet. See the following diagram: Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 70 Prepare the modem, CD-ROM drive, and tape drive for connection to the 201i server. For instructions, see Chapter 7 "Preparing peripheral devices" (page 89). Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 71: Chapter 6 Installing The 201I Server In The Communication Server 1000 System

    Call Server • Media Gateway • Media Gateway Expansion Call Server The Call Server provides telephony services and call processing. Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 72 100Base-T connectors for connecting Media Gateways using one of the following: — for connections over the LAN customer-supplied standard 100Base-T CAT5 Ethernet cables — for point-to-point connections (Nortel-supplied crossover Ethernet cables) • one 10Base-T Ethernet connector that — provides the ELAN subnet interface to management software applications, such as Optivity Telephony Manager and CallPilot —...
  • Page 73 201i server in a pair of consecutive slots in the Media Gateway or Media Gateway Expansion. The following table identifies the Media Gateway and Media Gateway Expansion slots into which you can install the CallPilot 201i server: The 201i server Unit...
  • Page 74 Note: Except for the back panel connectors, the Media Gateway Expansion is similar in external appearance to the Media Gateway. Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 75: Removing The Media Gateway Or Media Gateway Expansion Cover

    To access the interior of the Media Gateway or Media Gateway Expansion, you must remove the front bezel and inside front cover plate. Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 76 Action WARNING Risk of eye injury Nortel recommends that you operate the Media Gateway and Media Gateway Expansion with their front bezels installed. When the blue LEDs inside these units are lit, they are very bright. Remove the front bezel from the Media Gateway or Media Gateway Expansion as shown in the diagram on the next page.
  • Page 77: Installing The 201I Server

    Installing the 201i server Introduction This section describes how to install the 201i server inside the Media Gateway or Media Gateway Expansion. Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 78: 201I Server Hardware Installation

    Before you begin Determine which pair of consecutive slots are to contain the 201i server. The following table identifies the Media Gateway and Media Gateway Expansion slots into which the CallPilot 201i server can be installed: The 201i server Unit...
  • Page 79: 201I Server Hardware Installation

    —End— What is next? Continue with "Installing the NTRH3502 SCSI cable for Communication Server 1000" (page 80). Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 80: Installing The Ntrh3502 Scsi Cable For Communication Server 1000

    1. Before you install the SCSI devices in a daisy chain, you must configure the SCSI device IDs and DIP switches. For instructions, see Chapter 7 "Preparing peripheral devices" (page 89). Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 81: 201I Server Hardware Installation

    Media Gateway or Media Gateway Expansion. You will use one of the screws later to fasten the NTRH3502 SCSI cable drain wire. Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 82: Replacing The Media Gateway Or Media Gateway Expansion Cover

    To replace the inside front cover plate The following diagram provides an overview of how to install the inside front cover plate: Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 83: 201I Server Hardware Installation

    Tighten the screws to secure the front cover plate. Continue with ""To replace the front bezel" (page 83)," below. —End— To replace the front bezel Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 84: 201I Server Hardware Installation

    Action WARNING Risk of eye injury Nortel recommends that you operate the Media Gateway and Media Gateway Expansion with their front bezels installed. When the blue LEDs inside these units are lit, they are very bright. Align the two posts and the locking tab on the rear of the front bezel with the slots on the inside front cover plate.
  • Page 85: Connecting Cables To The Communication Server 1000 System

    Secure the connection by tightening the retaining screw and Velcro fastening strap of the conductor. The following diagram shows how to secure the multi I/O cable connection: Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 86: 201I Server Hardware Installation

    Gateway or Media Gateway Expansion. See the diagram in step 4. Connect the power cord to the Media Gateway or Media Gateway Expansion. Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 87: 201I Server Hardware Installation

    Prepare the modem, CD-ROM drive, and tape drive for connection to the 201i server. For instructions, see Chapter 7 "Preparing peripheral devices" (page 89). Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 88: 201I Server Hardware Installation

    88 Chapter 6 Installing the 201i server in the Communication Server 1000 system Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 89: Chapter 7 Preparing Peripheral Devices

    You can use an external SCSI tape drive to back up and restore data. Since the tape drive is an external device, it also requires its own AC power source. Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 90: Setting The Modem Dip Switches

    Note: The DIP switches are located on the back of the modem. ON is down. OFF is up. Default Function Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 91: 201I Server Hardware Installation

    Auto answer suppression • OFF: Modem answers on first ring, or higher if specified in NVRAM • ON: Disables auto answer Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 92: Setting The Cd-Rom Drive Scsi Id And Dip Switches

    To change the SCSI ID, use the blade of a screwdriver to rotate the SCSI ID dial arrow to 3. Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 93: 201I Server Hardware Installation

    If the CD-ROM drive is the first device and daisy chained with the tape drive, set this switch to OFF. Test OFF (for factory use only) Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 94: Setting The Tape Drive Scsi Id

    To change the SCSI ID, use the blade of a screwdriver to press either the plus (+) or minus (-) button on the SCSI ID switch. Set the SCSI ID to 5. Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 95: Setting Scsi Device Termination

    The first device in a SCSI device daisy chain can be either the tape drive or the CD-ROM drive. However, because the Tandberg SLR5 tape drive is already internally terminated at the factory, Nortel recommends that you connect the tape drive as the last device.
  • Page 96: 201I Server Hardware Installation

    "Installing the intermediate SCSI cable for Option 11C" (page 58) • "Installing the NTRH3502 SCSI cable for Option 11C Mini" (page 63) Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 97: 201I Server Hardware Installation

    For more information about the cabling requirements, see "Installing the NTRH3502 SCSI cable for Communication Server 1000" (page 80). Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 98: 201I Server Hardware Installation

    Complete the 201i server installation in the switch. See Chapter 8 "Connecting peripheral devices to the 201i server" (page 99). Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 99: Chapter 8 Connecting Peripheral Devices To The 201I Server

    "Installing the MPCs" (page 102) "Installing the monitor, keyboard, and mouse" (page 104) "Connecting the CD-ROM and tape drives" (page 105) "Connecting the 201i server to the switch, ELAN subnet , and Nortel server subnet" (page 113) "Connecting the modem" (page 116) "Completing the installation"...
  • Page 100: 201I Server Hardware Installation

    The modem must be connected to the 201i server if: • you want to administer the 201i server from a remote location that does not have access to the Nortel server subnet. • you need assistance from Nortel technical support.
  • Page 101: 201I Server Hardware Installation

    1. Set the DIP switches on the external fax modem. See "Setting the modem DIP switches" (page 90). Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 102: Installing The Mpcs

    • facing to the right if the 201i server is inserted into the 201i shelf (see the following diagram) Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 103 Note: Populate MPC slots in numerical order as listed on the 201i server faceplate. —End— What is next? Continue with "Installing the monitor, keyboard, and mouse" (page 104). Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 104: Installing The Monitor, Keyboard, And Mouse

    Once you have successfully started and configured the 201i server, remove the monitor, keyboard, and mouse. For day-to-day administration, use a web browser on a PC that is connected to the ELAN subnet or Nortel server subnet. Hardware requirement CAUTION Risk of equipment damage The mouse connector on the 201i faceplate is a PS/2 connector.
  • Page 105: Connecting The Cd-Rom And Tape Drives

    Introduction You can connect the CD-ROM, tape drive, or both to the intermediate SCSI cable that you installed earlier. Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 106: 201I Server Hardware Installation

    11C Mini, go to "To connect the CD-ROM and tape drives to the 201i server (Option 11C Mini)" (page 110). Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 107: 201I Server Hardware Installation

    SCSI cable supplied with the device or an NTRH3502 cable. The following diagram shows cable connections, where the CD-ROM is the first device: Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 108: 201I Server Hardware Installation

    To connect the CD-ROM and tape drives to the 201i server (Option 11C) Step Action Connect the first SCSI device. Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 109: 201I Server Hardware Installation

    SCSI cable supplied with the device or an NTRH3502 cable. The following diagram shows cable connections, where the CD-ROM drive is the first device: Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 110: 201I Server Hardware Installation

    To connect the CD-ROM and tape drives to the 201i server (Option 11C Mini) Step Action Connect the first SCSI device. Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 111: 201I Server Hardware Installation

    SCSI cable supplied with the device or an NTRH3502 cable. The following diagram shows cable connections, where the CD-ROM drive is the first device: Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 112: 201I Server Hardware Installation

    SCSI cable supplied with the device or an NTRH3502 cable. The following diagram shows cable connections, where the CD-ROM drive is the first device: Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 113: Connecting The 201I Server To The Switch, Elan Subnet , And Nortel Server Subnet 113

    Connecting the 201i server to the switch, ELAN subnet , and Nortel server subnet 113 Note: Alternate SCSI device connection scenarios are supported, but are not depicted in this guide. If you want to use a connection scenario that is not described in this guide, ensure that you use appropriate cabling for each SCSI device.
  • Page 114: 201I Server Hardware Installation

    Option 11C or Meridian 1 to the nearest backplane grounding bolt on the switch The following diagram shows drain wire connection on the Option 11C. Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 115: 201I Server Hardware Installation

    Connecting the 201i server to the switch, ELAN subnet , and Nortel server subnet 115 • Option 11C Mini or Communication Server 1000 to a screw on the back of the cabinet Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007...
  • Page 116: Connecting The Modem

    Connect the connector on the multi I/O cable that is labeled as ELAN to the switch network hub or switch. If Nortel server subnet is required, connect the connector on the multi I/O cable that is labeled as CLAN to the CLAN 10- or 100Base-T-compliant network hub or switch.
  • Page 117: 201I Server Hardware Installation

    Note: Ensure that the modem is receiving power by checking that at least one LED on its front panel is lit. Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 118: Completing The Installation

    To complete the installation of the 201i server, lock the 201i into position. The server starts up automatically. ATTENTION When connecting the optional Nortel server subnet, do not power up unless your antivirus programs and Nortel security updates are installed first. To complete the installation and start the 201i server Note: Ensure that the switch in which the 201i is installed is powered on.
  • Page 119: 201I Server Hardware Installation

    Proceed with the CallPilot <switch model> and CallPilot Server Configuration guide for your switch and server to connect and configure the server and switch. Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 120: Index

    116 starting 101, 118, 119 network 113 temperatures 18 switch 113 unpacking 32 connectors CLAN 22 ELAN 22 Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 121: 201I Server Hardware Installation

    Meridian 1 40, 42 device termination, setting 98 reason for moving 39 DIP switches, setting 93 connectors Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 122: 201I Server Hardware Installation

    13 documentation, Communication Server faceplate 14, 100 1000 75 backplane (tip and ring) cable 47 drain wire, connecting Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 123: 201I Server Hardware Installation

    78 existing cables, removing 44 large Meridian 1 systems 43 NTRH3501, installing 48 overview 28, 31 connection requirements 34 Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 124: 201I Server Hardware Installation

    Option 11C 114 multi I/O cable, installing 69 Option 11C Mini 69 power cable installing 69 SCSI cable 63 Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 125: 201I Server Hardware Installation

    SCSI connectors 17, 23 CD-ROM drive DIP switches 93 SCSI devices cabling diagrams device termination CD-ROM drive 98 Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 126: 201I Server Hardware Installation

    I/O cable 21 requirements 33 switches, setting DIP warning, working with the switch CD-ROM drive 93 backplane 44 modem 90 Nortel CallPilot 201i Server Hardware Installation NN44200-301 01.01 Standard 5.0 15 February 2007 Copyright © 2007, Nortel Networks Nortel Networks Confidential...
  • Page 128: 201I Server Hardware Installation

    Document version: 01.01 Document date: 15 February 2007 To provide feedback or report a problem in this document, go to www.nortel.com/documentfeedback. Sourced in Canada The information in this document is subject to change without notice. The statements, configurations, technical data, and recommendations in this document are believed to be accurate and reliable, but are presented without express or implied warranty.

Table of Contents