About the 201i server

Network requirements

Appropriate networking equipment must be available for both the CLAN
and ELAN.
The CLAN and ELAN must be properly configured for correct CallPilot
operation. To ensure correct configuration, Nortel recommends that you
consult a network specialist.
ATTENTION
Multi I/O cable description
The multi I/O cable contains four connectors, and is approximately 3 m
(10 ft) in length. See the following diagram:
Multi I/O cable NTRH0912
RJ-45 female-to-female gender change jack
Note: If you need more than 3 m (10 ft) of multi I/O cable, use the supplied RJ-45
female-to-female gender change jacks to attach additional cable. A maximum of
76.2 m (250 ft) is supported.
28
For important considerations about using the ELAN in
your network, see "About the ELAN" in the CallPilot
Installation and Configuration Task List.
Standard 1.07
Drain wire
50-pin
amphenol
connector
ELAN
connector
CLAN
connector
RS-232
connector
G101441
CallPilot