Installing System Monitor And Tty Cables - Nortel 1000 Manual

Fiber remote ipe fundamentals
Table of Contents

Advertisement

4
Figure 9 "Fiber Superloop Network card patchcord connections in Meridian
1 PBX 81C" (page 55)
81Cwith the NT1P61 Fiber Superloop Network card and patchcords
installed.
Figure 9
Fiber Superloop Network card patchcord connections in Meridian 1 PBX 81C

Installing system monitor and TTY cables

The system monitor cable is normally installed in the factory and does not
have to be installed at the site. The cable that must be installed at the site
is the cable connecting the terminal or TTY to the RJ-45 connector located
on the I/O panel located at the rear of the module containing the NT1P61
Fiber Superloop Network card.
Plug the other NT1P75 fiber-optic patchcord FC/PC optical
connectors into connectors at the optical I/O patch-panel at the
rear of the module.
Use Tx and Rx designators to identify transmit and receive
patchcord connectors. Repeat this step for all patchcords.
shows the Core/Net module of a Meridian 1 PBX
Nortel Communication Server 1000
Fiber Remote IPE Fundamentals
NN43021-554 04.01 4 June 2010
Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
Fiber-optic equipment installation 55
--End--