Preparing for installation

Switch and network requirements

Introduction
The information in this section will help you plan your 201i server
installation.
Meridian 1 or Succession 1000 slot requirements
The 201i server occupies two physical and electrical slots.
You must install the 201i server in two peripheral equipment slots as
follows:
Switch
Meridian 1 tiered
systems
Option 11C
Option 11C Mini
44
Slots
0 through 14
Ensure that both slots have electrical backplane
connectivity.
1 through 9 in any Option 11C cabinet
Note: Both of the server backplane connectors must
be installed in slots 1 through 9 to receive proper
power. Neither connector can reside in slot 10.
A pair of consecutive slots in any cabinet
Note: You cannot install the 201i server in slots 0 or
4 because these slots are dedicated to other cards. For
more information about cards and slots, refer to the
Option 11C Mini documentation.