Command
IP Setup (continued)
Set subnet mask
14, 24
View subnet mask
Set gateway IP
address
14, 24
View gateway IP address
Set all at once
View connections listing
Password and Security Settings
Set administrator
password
24
Clear administrator
password
24
View administrator
password
24
Set user password
24
Clear user password
24
View user password
24
IP address in the format
X7$
NOTE:
=
in setting values and are suppressed in returned values. Factory default address (when DHCP is
turned off) is
X7%
=
Subnet mask (nnn.nnn.nnn.nnn). The syntax is the same as for IP addresses. Leading zeros are
optional in setting values in each of the four fields, and are suppressed in returned values.
X7$
=
Gateway address (nnn.nnn.nnn.nnn). Set IP address for your gateway. Leading zeros are optional.
Prefix (subnet mask bits). Subnet 255.255.0.0 is represented as a prefix value by /16
X7^
=
X7&
=
Administrator or user password, 12 characters maximum. / \ | * and space characters are not
allowed. Passwords are case-sensitive.
ASCII Command
(Host to Unit)
E X7%
}
CS
E
}
CS
E X7$
}
CG
E
}
CG
E
X7$
}
1 *
CISG
E
}
CC
E X7&
}
CA
E
}
• CA
E
}
CA
E X7&
}
CU
E
}
• CU
E
}
CU
nnn.nnn.nnn.nnn
.
192.168.254.254
Response
(Unit to Host)
X7% ]
Ips •
X7% ]
With tagged responses
(verbose modes 2 and 3):
X7% ]
Ips
X7$ ]
Ipg •
X7$ ]
With tagged responses
(verbose modes 2 and 3):
X7$ ]
Ipg
X7$
X7^
X7$]
Cisg 1 *
/
*
{Number of
]
connections}
With tagged responses
(verbose modes 2 and 3):
Icc {Number of
]
connections}
X7& ]
Ipa •
]
Ipa •
]
****
With tagged responses
(verbose modes 2 and 3):
]
Ipa ****
X7& ]
Ipu •
]
Ipu •
]
****
With tagged responses
(verbose modes 2 and 3):
]
Ipu ****
). Leading zeros in each of the four fields are optional
MediaPort 200 • Remote Configuration and Control
Additional Description
X7%
Set subnet mask
for the unit.
X7%
View unit subnet mask
.
X7$
Set gateway IP address
for
the unit.
View unit gateway IP address
Set IP address, subnet mask, and
gateway address all-at-once and
reboot.
View the number of connections
to the MediaPort.
Example: Icc17
X7&
Set password
for the unit.
Passwords are case-sensitive.
Remove the administrator
password from the unit. The user
password is also removed.
The actual password cannot
be viewed. Four asterisks are
returned instead. If there is no
password, **** is omitted from
the response.
X7&
Set password
for the unit.
Passwords are case-sensitive.
Remove the user password from
the unit.
The actual password cannot
be viewed. Four asterisks are
returned instead. If there is no
password, **** is omitted from
the response.