Extron electronics mediaport 200 User Manual page 73

Hdmi and audio to usb scaling bridge
Hide thumbs Also See for mediaport 200:
Table of Contents

Advertisement

Command
Port Assignment
Notes:
Duplicate port number assignments are not permitted (that is, the Telnet and web port numbers cannot be the same)
and result in an E13 error message.
Remapping of ports other than to reset them to defaults (23 or 80) or disabling them (setting to 0) must be to port
numbers equal to or greater than 1024.
Set Telnet port map
24
Reset Telnet port map
24
Disable Telnet port
24
View Telnet port map
24
Set web port map
24
Reset web port
24
24
Disable web port
View web port map
24
Set SNMP port map
24
Reset SNMP port map
24
24
Disable SNMP port
View SNMP port map
24
ASCII Command
(Host to Unit)
E
}
{port#} MT
E
}
23MT
E
}
0MT
E
}
MT
E
}
{port#} MH
E
}
80MH
E
}
0MH
E
}
MH
E
}
A {port#} PMAP
E
}
A 0 161PMAP
E
}
A 161PMAP
E
}
A PMAP
Response
(Unit to Host)
]
Pmt {port number}
]
Pmt 00023
]
Pmt 00000
]
{port#}
]
Pmh {port number}
]
Pmt 00080
]
Pmh 00000
]
{port#}
]
Pmap A(port number}
]
Pmap A 00161
]
Pmap A 00000
]
{port#}
MediaPort 200 • Remote Configuration and Control
Additional Description
Set Telnet port number.
Reset the Telnet port number to
the default (23).
Disable the Telnet port.
View the current Telnet port
selection.
Set the web port number.
Reset the web port number to the
default (80).
Disable the web port.
View the current web port
selection.
Set the SNMP port number.
Reset the SNMP port number to
the default (161).
Disable the SNMP port.
View the current SNMP port
selection.
67

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents