Command
Advanced Configuration (continued)
Reset
Reset to factory
defaults
24
This reset is product-dependent. Receive timeouts are reset to defaults and port redirects are terminated. This
NOTE:
reset excludes IP settings such as IP address, subnet mask, gateway address, and the IP security-level table. It does
not remove the file system.
Erase all files from flash
memory
NOTE:
This reset removes only files created in the user space, which includes those created by the backup and restore
functions, software configuration tools, image captures, user logo files, and other user-supplied HTML files. Space used
by firmware for internal operations such as saving non-volatile settings is not removed.
Absolute reset retaining
IP settings
NOTE:
This reset removes all device settings, including the file system and passwords, but retains IP settings such as IP
address, subnet mask, gateway address, DHCP setting, and port mapping (Telnet, web, and direct access) in order to
preserve communication with the device. This reset is recommended after a firmware update.
Reboot system
24
Restart network
24
Absolute system reset
IP system reset
NOTE:
This reset returns only IP settings such as IP address, subnet mask, gateway address, DHCP setting, and port
mapping (Telnet, web, and direct access) to factory values.
Information Requests
General information
Query model name
Query unit description
Query system memory
usage
X#
NOTE:
=
Input video format: 0 = No input signal detected, 1 = DVI, 2 = HDMI
X1)
=
Host presence or USB output video streaming: 0 = not detected, 1 = detected
X1#
=
Horizontal and vertical frequencies. Expressed as 3 digits with one decimal place and leading zeros.
X4@
=
Video mute status: 0 = off (unmute) (default), 1 = on (mute to black screen), 2 = on (mute sync and video)
X5(
=
USB audio type: 0 = none (input audio muted), 1 = LPCM 2-Ch, 5 = Multi-Ch (return audio only)
X6)
=
USB standard: 0 = None (no host), 1 = USB 1.1, 2 = USB 2.0, 3 = USB 3.0
ASCII Command
(Host to Unit)
E
}
ZXXX
E
}
ZFFF
E
}
ZY
E
}
1 Boot
E
}
2 Boot
E
}
ZQQQ
E
}
1ZQQQ
I
1I
2I
3i
Response
(Unit to Host)
]
Zpx
]
Zpf
]
Zpy
]
Boot 1
]
Boot 2
]
Zpq
]
Zpq1
X#
X4@
X1#
Typ
• Blk
• Hrt
With tagged responses (verbose modes 2 and 3):
X#
X4@
Inf * Typ
• Blk
• Hrt
]
MediaPort 200
HDMI and Audio to USB Scaling Bridge
With tagged responses (verbose modes 2 and 3):
Inf02 * HDMI and Audio to USB Scaling Bridge
{Bytes used out of
]
total Kbytes}
MediaPort 200 • Remote Configuration and Control
Additional Description
Reset all device settings to factory
default settings.
Erase all files from flash (user)
memory.
Reset all device settings to factory
defaults but retain IP settings.
Reboot the unit.
Reset all device settings to the
factory defaults, retaining the
firmware version.
Reset only IP settings to factory
defaults.
X1# ]
• Vrt
X1#
X1# ]
• Vrt
View video input signal type (Typ),
video mute status (Blk), and
horizontal (Hrt) and vertical (Vrt)
frequencies.
View the product name.
]
]
View the model description.
View the number of memory
bytes that have been used out
of the total number of Kbytes
of system memory.