Extron electronics mediaport 200 User Manual page 58

Hdmi and audio to usb scaling bridge
Hide thumbs Also See for mediaport 200:
Table of Contents

Advertisement

X5(
= USB audio type
0 = None — input is muted.
1 = LPCM 2-Ch
X6)
= USB standard
0 = None — no host
1 = USB 1.1
X6!
= Video signal status
0 = Video or TMDS signal not detected
1 = Video or TMDS packet signal detected
X6@
= Input HDCP authorized
0 = Input HDCP Authorized disabled (default)
1 = Input HDCP Authorized enabled
X6(
= (Ethernet only) Number of seconds (stated in tens of seconds) before timeout on IP
connections
Minimum = 1 (10 seconds)
Maximum = 65000 (650,000 seconds)
Default = 30 (300 seconds)
Each step = 10 seconds
The response contains leading zeros.
If no data is received during the timeout period, the Ethernet connection is closed. When the
unit is connected via RS-232 or USB, only the global timeout commands apply. Anything else
returns an E13 error code.
X7)
= Local date and time
Set format: MM/DD/YY-HH:MM:SS
Example: 06/21/15-10:54:00
{day of the week}
View format: Www
Example: Fri, 26 Sep 2015 18:19:33
X7!
= Greenwich Mean Time (GMT) offset value (-12:00 through 14:00) in hours and
minutes (hh:mm)
X7@
=
A 2- to 6-digit code, such as "PST" for GMT - 8.00
X7#
=
UTC offset and location name, such as (UTC-08:00) Pacific Time for PST
=
X7$
IP address (nnn.nnn.nnn.nnn). Leading zeros in each of the four fields are optional in
setting values and are suppressed in returned values.
Factory default address (when DHCP is turned off) is 192.168.254.254.
X7%
= Subnet mask (nnn.nnn.nnn.nnn). Leading zeros are optional in setting values in each of
the four fields, and are suppressed in returned values.
X7^
= Prefix (subnet mask bits)
Default subnet mask 255.255.00.000 is represented as a prefix value as /16.
X7&
= Password (12 characters maximum) The following characters are not allowed: / \ | *
and {space}. Passwords are case-sensitive.
NOTE:
A user password cannot be assigned if no administrator password exists. An
E14 error code is returned. If the administrator password is cleared, the user password
and all extended security level passwords are also removed.
X7(
= Serial port baud rate
X8)
= Serial port parity
X8!
= Serial port number of data bits
X8@
= Serial port number of stop bits
X8#
= Hardware (MAC) address (xx-xx-xx-xx-xx-xx)
2 = USB 2.0
3 = USB 3.0
, DD Mmm YYYY HH:MM:SS
MediaPort 200 • Remote Configuration and Control
52

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents