Cooling system and lubrication system
If the "overflow" tube was previously removed, reposi-
tion it and fasten with the three rubber clamps (1) as
shown in the figure.
Ensure that the placement follows the figure and inclu-
1
des also the clutch control piping (2).
2
Put the overflow pipe (1) on the nozzle of the expan-
sion tank cap (2) again, until it reaches the reference
limit shown in the figure.
2
1
L
Assemble the ignition switch (1) securing it on the
fixing support using the two screws (2).
8÷10 N•m
Screw tightening torque (2): 8 ÷ 10 N•m
Thread-locking fluid used: Loctite 243