Fuji Xerox ApeosPort-IV C7780 Administrator's Manual page 456

Hide thumbs Also See for ApeosPort-IV C7780:
Table of Contents

Advertisement

15 Problem Solving
The print queue where the
user has transmitted the print
data, is not assigned to the
machine.
Print data format and the
print environment settings on
the computer do not match.
The number of print queues
set for the machine exceeds
the maximum number
allowed.
The slave file server is not
configured. ([Bindery
Service] mode)
Printer type do not match.
The slave file server
configuration is mismatched.
([Bindery Service] mode)
The form number on the print
data and the form number
set to the printer do not
match.
15
The level settings for the IPX
checksum do not match.
*: For more information on configuration and operations, refer to NetWare Online Documentation.
456
Cause
Use NWADMIN from a
computer to check the print
queue's [Assignment]
whether the machine is
assigned in the printer list
serviced by the print queue.*
Use NWADMIN from a
computer to check on the
print queue list of
[Assignment] for the
machine whether the desired
print queue is assigned.*
Use PCONSOLE from a
computer to confirm whether
the slave file server is
registered to [Service
NetWare Server] on the print
server indicated by [Print
Server Information].*
Use PCONSOLE from a
computer to confirm whether
the printer type is set to
parallel, the port is set to
LPT1, and the location is set
to automatic mode (local),
under [Print Server
Information] > [Printer] >
[Printer xxx Environment
Configuration].*
Use PCONSOLE from a
computer to confirm whether
the printer type is set to
[Defined Elsewhere] under
[Print Server Information] >
[Printer] > [Printer xxx
Environment Settings].*
Use NWADMIN on a
computer to select the
machine and confirm
whether the start number of
the form in the environment
settings matches the number
in the print data.*
Use the set command from
the console screen on the
file server to confirm whether
the IPX checksum is set to
level 2.
Check point
Re-send the print data to the
print queue which is
assigned to the machine.*
Use NWADMIN from a
computer to add the print
queue to the machine.*
If the computer is running on
-
Windows, set it not to output
<Ctrl>-D.
Re-send the print data to the
print queue which is
assigned to the machine.*
Use PCONSOLE from
computer to register the
slave file server and reflect
the configured settings.*
Use PCONSOLE from
computer to set the printer
type to parallel, the port to
LPT1, and the location to
automatic mode (local), and
then reflect the configured
settings.
If the printer type is not set to
[Defined Elsewhere], change
it to [Defined Elsewhere],
and then reflect the
configured settings.*
Use NWADMIN from a
computer to match the [Start
Form] number in the
machine's environment
settings to the number in the
print data.*
Enter the following command
from the console screen on
the file server to set the IPX
checksum to either level 0 or
level 1.
set Enable IPX Checksum=x
(x = 0 or 1)
Remedy

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents