3) Remove center ventilation louver referring to Step 1)
and 2) of "Information Display (Clock) Removal and
Installation".
4) Remove combination meter cluster panel (1) pulling
it in arrow direction shown in figure.
5) Remove screws (1) fastening combination meter.
6) Remove combination meter (2) pulling it arrow
direction as shown.
2
Installation
Reverse removal procedure.
Fuel Level Sensor Removal and Installation
Removal
Remove fuel pump assembly referring to "Fuel Pump
Assembly Removal and Installation in Section 1G".
Installation
Install fuel pump assembly referring to "Fuel Pump
Assembly Removal and Installation in Section 1G".
Fuel Level Sensor Inspection
• Check that resistance between terminals "a" and "b"
of fuel level sensor changes with change of float
position.
• Check resistance between terminals "a" and "b" at
each float position in the following.
If the measured value is out of specification, replace.
Fuel level sensor specifications
Float Position
204 mm
Full Upper "c"
(8.03 in.)
32 mm
Full Lower "d"
(1.26 in.)
1
I5RW0A930009-01
1
I4RS0A930012-02
S6RW0D9306004
S6RW0D9306005
Resistance (Ω)
40 ± 2
280 ± 3.3
Instrumentation / Driver Info. / Horn:
"a"
"b"
2
"c"
"d"
1. Fuel pump
Oil Pressure Switch Removal and Installation
For removal and installation, refer to "Oil Pressure
Check in Section 1E".
Oil Pressure Switch Inspection
1) Disconnect oil pressure switch (1) lead wire.
2) Check for continuity between oil pressure switch
terminal (2) and cylinder block (3) as shown.
If check result is not as specified, replace oil
pressure switch (1).
Oil pressure sensor specification
During engine running: No continuity
At engine stop: Continuity
4. Engine oil filter
9C-15
1
I7RW01930008-01
2. Float
S6RW0D9306006
S6RW0D9306007
I3RM0A930009-01
F: Front