3 COMMON PARAMETERS
(3) External signal input
Servo external signal (Upper stroke limit/Lower stroke limit/Stop signal/Proximity
dog) can be selected for every axis from the following two methods.
(a) Q172DLX Servo external signals interface module use
Set the servo external signals interface module, and set axis No. as the
"External signal setting" in the system setting.
(b) Servo amplifier input device use (MR-J3- B use only)
Set "Amplifier input valid" as the external signal input setting in the "Amplifier
setting" of system setting.
There are following restrictions to use.
• Count type home position return cannot be used.
• Speed/position switching control cannot be executed.
• Stop signal (STOP) cannot be used.
The correspondence of external signal and input device is shown below.
External signals
Upper stroke limit (FLS)
Lower stroke limit (RLS)
Proximity dog (DOG)
(Note): Refer to the "MR-J3- B Servo Amplifier Instruction Manual" for pin configurations.
Set the external signal setting in the "Input Filter Setting".
Input device (CN3)
3 - 14
(Note)
DI1
DI2
DI3

Advertisement

Table of Contents

   Also See for Mitsubishi Electric MOTION CONTROLLERS Q172DCPU

   Related Manuals for Mitsubishi Electric MOTION CONTROLLERS Q172DCPU

This manual is also suitable for:

Q173dcpu

Comments to this Manuals

Symbols: 0
Latest comments:
  • p Dec 14, 2015 07:47:
    This video describes how to eliminate the 'InS' message on a Mitsubishi Q Series motion controller by ...
  • p Dec 14, 2015 07:32:
    This video describes how to eliminate the 'InS' message on a Mitsubishi Q Series motion controller by